Whirlpool WOEC5030LZ Owners Manual - Page 12

Make Electrical Connection, Wire Cable from Home Power Supply

Page 12 highlights

Make Electrical Connection IMPORTANT: For Flush installation before making electrical connection, the oven feet or spacers need to be installed to allow a microwave/oven combination to be installed in a recommended cutout height. Please contact service for feet to be shipped to you free of charge. Electrical Connection Options Chart If your home has: Go to section: 4-wire 4-Wire Cable from Home Power Supply WARNING 3-wire (1.13/2c"m) 3-Wire Cable from Home Power Supply Electrical Shock Hazard Disconnect power before servicing. Use 8 gauge copper wire. Electrically ground oven. Failure to follow these instructions can result in death, fire, or electrical shock. This oven is manufactured with a neutral (white) power supply wire and a cabinet-connected green (or bare) ground wire. 1. Disconnect power. 2. Feed the flexible conduit from the oven through the opening in the cabinet. 3. Remove junction box cover, if it is present. 4. Install a UL listed or CSA approved conduit connector to the junction box. A A. UL listed or CSA approved conduit connector 5. Route the flexible conduit from the oven to the junction box through a UL listed or CSA approved conduit connector. 6. Tighten screws on conduit connector. 7. See "Electrical Connection Options Chart" to complete installation for your type of electrical connection. (1.13/2c"m) 4-Wire Cable from Home Power Supply IMPORTANT: Use the 4-wire cable from home power supply in the U.S. where local codes do not allow grounding through neutral, New Branch circuit installations (1996 NEC), mobile homes and recreational vehicles, new construction and in Canada. A B E F G H C I D A. Cable from home power supply F. White wires B. Black wires G. UL listed wire connectors C. Red wires H. Green (or bare) ground wires D. 4-wire flexible conduit from I. UL listed or CSA approved oven conduit connector E. Junction box 1. Connect the 2 black wires (B) together using a UL listed wire connector. 2. Connect the 2 red wires (C) together using a UL listed wire connector. 3. Connect the 2 white wires (F) together using a UL listed wire connector. 4. Connect the green (or bare) ground wire (H) from the oven cable to the green (or bare) ground wire (in the junction box) using a UL listed wire connector. 5. Install junction box cover. 12

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

12
Make Electrical Connection
IMPORTANT:
For Flush installation before making electrical
connection, the oven feet or spacers need to be installed to allow
a microwave/oven combination to be installed in a recommended
cutout height.
Please contact service for feet to be shipped to you free of charge.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper wire.
Electrically ground oven.
Failure to follow these instructions can result in death,
fire, or electrical shock.
This oven is manufactured with a neutral (white) power supply
wire and a cabinet-connected green (or bare) ground wire.
1.
Disconnect power.
2.
Feed the flexible conduit from the oven through the opening in
the cabinet.
3.
Remove junction box cover, if it is present.
4.
Install a UL listed or CSA approved conduit connector to the
junction box.
A
A. UL listed or CSA approved conduit connector
5.
Route the flexible conduit from the oven to the junction box
through a UL listed or CSA approved conduit connector.
6.
Tighten screws on conduit connector.
7.
See “Electrical Connection Options Chart” to complete
installation for your type of electrical connection.
Electrical Connection Options Chart
If your home has:
Go to section:
4-wire
1/2"
(1.3 cm)
4-Wire Cable from Home
Power Supply
3-wire
1/2"
(1.3 cm)
3-Wire Cable from Home
Power Supply
4-Wire Cable from Home Power Supply
IMPORTANT:
Use the 4-wire cable from home power supply in
the U.S. where local codes do not allow grounding through
neutral, New Branch circuit installations (1996 NEC), mobile
homes and recreational vehicles, new construction and in
Canada.
A
D
F
H
B
C
E
G
I
A.
Cable from home power supply
B.
Black wires
C.
Red wires
D.
4-wire flexible conduit from
oven
E.
Junction box
F.
White wires
G.
UL listed wire connectors
H.
Green (or bare) ground wires
I.
UL listed or CSA approved
conduit connector
1.
Connect the 2 black wires (B) together using a UL listed wire
connector.
2.
Connect the 2 red wires (C) together using a UL listed wire
connector.
3.
Connect the 2 white wires (F) together using a UL listed wire
connector.
4.
Connect the green (or bare) ground wire (H) from the oven
cable to the green (or bare) ground wire (in the junction box)
using a UL listed wire connector.
5.