Yamaha M3000A Owner's Manual - Page 36
Using mute groups, change numbers 105-112 which correspond - 56 channel
View all Yamaha M3000A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 36 highlights
About the Scene Memory function Control No. ON/EDIT Switch Control No. ON/EDIT Switch 60 CH INPUT 56 61 MIX 1 OUT 62 MIX 2 OUT 63 MIX 3 OUT 64 MIX 4 OUT 65 MIX 5 OUT 66 MIX 6 OUT 67 MIX 7 OUT 68 MIX 8 OUT 69 STEREO A OUT 70 71 72 73 MIX 9 OUT 74 MIX 10 OUT 75 MIX 11 OUT 76 MIX 12 OUT 77 MIX 13/14 OUT 78 MIX 15/16 OUT 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 MUTE GROUP 1 106 MUTE GROUP 2 107 MUTE GROUP 3 108 MUTE GROUP 4 109 MUTE GROUP 5 110 MUTE GROUP 6 111 MUTE GROUP 7 112 MUTE GROUP 8 113 114 115 116 117 118 119 • If the CC (control change) parameter of utility mode is set to " " (mute group), only control change numbers (105-112) which correspond to mute groups will be transmitted or received. Using mute groups When the utility mode oP (recall operation) parameter is set to " " (refer to page 34), the DIRECT RECALL 1-8 switches will function as "mute group" switches, and the scenes of memory numbers 1-8 can be used as mute groups. If two or more DIRECT RECALL switches are turned on, channels or buses which are off (muted) in the corresponding scenes will be turned off (while the ON status stored in these scenes is ignored). The following diagram shows the difference in operation between when the oP parameter is set to " " (direct recall) and " " (Mute group). If the oP parameter is set to " ," recalling a new scene will cause the channels or buses to be switched on/off according to the settings saved in that scene. In contrast if this parameter is set to " ," two or more DIRECT RECALL 1-8 switches can be turned on, and all channels or buses which are muted (off) in any of the mute groups will be muted. Mute group 1 (scene memory number 1) CHECK ON ON/ EDIT CHECK ON ON/ EDIT CHECK ON ON/ EDIT CHECK ON ON/ EDIT CHECK ON ON/ EDIT MUTE ON (OFF) ON MUTE ON (OFF) Mute group 3 (scene memory number 3) CHECK ON ON/ EDIT CHECK ON ON/ EDIT CHECK ON ON/ EDIT CHECK ON ON/ EDIT CHECK ON ON/ EDIT ON ON ON When Direct Recall is used MUTE MUTE (OFF) (OFF) 1 2 The on/off settings of memory number 1 3 are recalled CHECK CHECK CHECK CHECK CHECK 4 ON ON ON ON ON ON/ ON/ ON/ ON/ ON/ EDIT EDIT EDIT EDIT EDIT 5 6 OFF ON ON OFF ON 7 8 1 2 Switch to the on/off settings of memory 3 number 3 CHECK CHECK CHECK CHECK CHECK 4 ON ON ON ON ON ON/ ON/ ON/ ON/ ON/ EDIT EDIT EDIT EDIT EDIT 5 ON ON ON OFF OFF 6 7 8 36