Yamaha PSR-S950 Data List - Page 48

Effect Parameter List / Liste der Effektparameter / Liste des paramètres d’effets / Lista de parámetros de efectos

Page 48 highlights

Effect Parameter List / Liste der Effektparameter / Liste des paramètres d'effets / Lista de parámetros de efectos • Parameters marked with a ● in the "Control" column can be controlled from an AC1 (assignable controller 1) etc. However, these only affect insertion type effects. • The "Table" column indicates the corresponding table number in the Effect Data Assign Table. • Parameter 10 Dry/Wet only affects insertion type effects. REVERB REVERB BASIC HALL, LIGHT HALL, HALL1, HALL2, HALL3, HALL4, HALL5, HALL M, HALL L, ATMO HALL, VOCAL HALL1, VOCAL HALL2, ACOSTIC ROOM, DRUMS ROOM, PERC ROOM, ROOM1, ROOM2, ROOM3, ROOM4, ROOM5, ROOM6, ROOM7, ROOM S, ROOM M, ROOM L, STAGE1, STAGE2, STAGE3, STAGE4, PLATE1, PLATE2, PLATE3, GM PLATE No. Parameter 1 Reverb Time 2 Diffusion 3 Initial Delay 4 HPF Cutoff 5 LPF Cutoff 6 7 8 9 10 Dry/Wet 11 Reverb Delay 12 Density 13 ER/Reverb Balance 14 High Damp 15 Feedback Level 16 Display 0.3s - 30.0s 0 - 10 0.1ms - 200.0ms (192step) 0.1ms - 99.3ms (96step) 0.1ms - 99.3ms (48step) Thru, 22Hz - 8.0kHz 1.0kHz - 18kHz, Thru Value 0 - 69 0 - 10 0 - 127 0 - 63 0 - 63 0 - 52 34 - 60 D63>W - D=W - DR - E=R - EW - D=W - DW - D=W - DR - E=R - EW - D=W - DW - D=W - DW - D=W - D

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97

PSR-S950/S750 Data List
48
Parameters marked with a
in the “Control” column can be controlled from an AC1
(assignable controller 1) etc. However, these only affect insertion type effects.
The “Table” column indicates the corresponding table number in the Effect Data Assign Table.
Parameter 10 Dry/Wet only affects insertion type effects.
REVERB
BASIC HALL, LIGHT HALL, HALL1, HALL2, HALL3, HALL4, HALL5, HALL M, HALL L,
ATMO HALL, VOCAL HALL1, VOCAL HALL2,
ACOSTIC ROOM, DRUMS ROOM, PERC ROOM, ROOM1, ROOM2, ROOM3, ROOM4,
ROOM5, ROOM6, ROOM7, ROOM S, ROOM M, ROOM L,
STAGE1, STAGE2, STAGE3, STAGE4, PLATE1, PLATE2, PLATE3, GM PLATE
REVERB
BALLAD HALL, PIANO HALL, LARGE HALL, MEDIUM HALL, WARM ROOM, WOODY
ROOM, RICH PLATE
REVERB
TUNNEL, CANYON, BASEMENT, WHITE ROOM
DELAY
DELAY LCR1, DELAY LCR2
DELAY
DELAY LR
DELAY
ECHO
REVERB
No.
Parameter
Display
Value
Table
Control
1
Reverb Time
0.3s – 30.0s
0 – 69
table#4
2
Diffusion
0 – 10
0 – 10
3
Initial Delay
0.1ms – 200.0ms (192step)
0 – 127
table#5
0.1ms – 99.3ms (96step)
0 – 63
0.1ms – 99.3ms (48step)
0 – 63
4
HPF Cutoff
Thru, 22Hz – 8.0kHz
0 – 52
table#3
5
LPF Cutoff
1.0kHz – 18kHz, Thru
34 – 60
table#3
6
7
8
9
10
Dry/Wet
D63>W – D=W – D<W63
1 – 127
11
Reverb Delay
0.1ms – 200.0ms (192step)
0 – 127
table#5
0.1ms – 99.3ms (96step)
0 – 63
0.1ms – 99.3ms (48step)
0 – 63
12
Density
0 – 4 (192step, 96step)
0 – 4
0 – 2 (48step)
0 – 2
13
ER/Reverb Balance
E63>R – E=R – E<R63
1 – 127
14
High Damp
0.1 – 1.0
1 – 10
15
Feedback Level
-63 – 0 – +63
1 – 127
16
No.
Parameter
Display
Value
Table
Control
1
Reverb Time
0.3s – 30.0s
0 – 69
table#4
2
Diffusion
0 – 10
0 – 10
3
Initial Delay
0.1ms – 200.0ms
0 – 127
table#5
4
HPF Cutoff
Thru, 22Hz – 8.0kHz
0 – 52
table#3
5
LPF Cutoff
1.0kHz – 18kHz, Thru
34 – 60
table#3
6
7
8
9
10
Dry/Wet
D63>W – D=W – D<W63
1 – 127
11
12
13
14
High Damp
0.1 – 1.0
1 – 10
15
16
No.
Parameter
Display
Value
Table
Control
1
Reverb Time
0.3s – 30.0s
0 – 69
table#4
2
Diffusion
0 – 10
0 – 10
3
Initial Delay
0.1ms – 200.0ms (192step)
0 – 127
table#5
0.1ms – 99.3ms (96step)
0 – 63
4
HPF Cutoff
Thru, 22Hz – 8.0kHz
0 – 52
table#3
5
LPF Cutoff
1.0kHz – 18kHz, Thru
34 – 60
table#3
6
Width
0.5m – 30.2m (192step)
0 – 104
table#11
0.5m – 10.2m (96step)
0 – 37
7
Height
0.5m – 30.2m (192step)
0 – 104
table#11
0.5m – 20.2m (96step)
0 – 73
8
Depth
0.5m – 30.2m
0 – 104
table#11
9
Wall Vary
0 – 30
0 – 30
10
Dry/Wet
D63>W – D=W – D<W63
1 – 127
11
Reverb Delay
0.1ms – 200.0ms (192step)
0 – 127
table#5
0.1ms – 99.3ms (96step)
0 – 63
12
Density
0 – 4
0 – 4
13
ER/Reverb Balance
E63>R – E=R – E<R63
1 – 127
14
High Damp
0.1 – 1.0
1 – 10
15
Feedback Level
-63 – 0 – +63
1 – 127
16
DELAY
No.
Parameter
Display
Value
Table
Control
1
Lch Delay
0.1ms – 1638.3ms (96step)
1 – 16383
0.1ms – 1486.0ms (48step)
1 – 14860
2
Rch Delay
0.1ms – 1638.3ms (96step)
1 – 16383
0.1ms – 1486.0ms (48step)
1 – 14860
3
Cch Delay
0.1ms – 1638.3ms (96step)
1 – 16383
0.1ms – 1486.0ms (48step)
1 – 14860
4
Feedback Delay
0.1ms – 1638.3ms (96step)
1 – 16383
0.1ms – 1486.0ms (48step)
1 – 14860
5
Feedback Level
-63 – 0 – +63
1 – 127
6
Cch Level
0 – 127
0 – 127
7
High Damp
0.1 – 1.0
1 – 10
8
9
10
Dry/Wet
D63>W – D=W – D<W63
1 – 127
11
12
13
EQ Low Frequency
32Hz – 2.0kHz
4 – 40
table#3
14
EQ Low Gain
-12dB – 0dB – +12dB
52 – 76
15
EQ High Frequency
500Hz – 16.0kHz
28 – 58
table#3
16
EQ High Gain
-12dB – 0dB – +12dB
52 – 76
No.
Parameter
Display
Value
Table
Control
1
Lch Delay
0.1ms – 1638.3ms (96step)
1 – 16383
0.1ms – 1486.0ms (48step)
1 – 14860
2
Rch Delay
0.1ms – 1638.3ms (96step)
1 – 16383
0.1ms – 1486.0ms (48step)
1 – 14860
3
Feedback Delay 1
0.1ms – 1638.3ms (96step)
1 – 16383
0.1ms – 1486.0ms (48step)
1 – 14860
4
Feedback Delay 2
0.1ms – 1638.3ms (96step)
1 – 16383
0.1ms – 1486.0ms (48step)
1 – 14860
5
Feedback Level
-63 – 0 – +63
1 – 127
6
High Damp
0.1 – 1.0
1 – 10
7
8
9
10
Dry/Wet
D63>W – D=W – D<W63
1 – 127
11
12
13
EQ Low Frequency
32Hz – 2.0kHz
4 – 40
table#3
14
EQ Low Gain
-12dB – 0dB – +12dB
52 – 76
15
EQ High Frequency
500Hz – 16.0kHz
28 – 58
table#3
16
EQ High Gain
-12dB – 0dB – +12dB
52 – 76
No.
Parameter
Display
Value
Table
Control
1
Lch Delay1
0.1ms – 1486.0ms (96step)
1 – 14860
0.1ms – 743.0ms (48step)
1 – 7430
2
Lch Feedback Level
-63 – 0 – +63
1 – 127
3
Rch Delay1
0.1ms – 1486.0ms (96step)
1 – 14860
0.1ms – 743.0ms (48step)
1 – 7430
4
Rch Feedback Level
-63 – 0 – +63
1 – 127
5
High Damp
0.1 – 1.0
1 – 10
6
Lch Delay2
0.1ms – 1486.0ms (96step)
1 – 14860
0.1ms – 743.0ms (48step)
1 – 7430
7
Rch Delay2
0.1ms – 1486.0ms (96step)
1 – 14860
0.1ms – 743.0ms (48step)
1 – 7430
8
Delay2 Level
0 – 127
0 – 127
9
10
Dry/Wet
D63>W – D=W – D<W63
1 – 127
11
12
13
EQ Low Frequency
32Hz – 2.0kHz
4 – 40
table#3
14
EQ Low Gain
-12dB – 0dB – +12dB
52 – 76
15
EQ High Frequency
500Hz – 16.0kHz
28 – 58
table#3
16
EQ High Gain
-12dB – 0dB – +12dB
52 – 76
Effect Parameter List / Liste der Effektparameter /
Liste des paramètres d’effets / Lista de parámetros de efectos