Yamaha SP2060 SP2060 V1.3 Supplementary Manual

Yamaha SP2060 Manual

Yamaha SP2060 manual content summary:

  • Yamaha SP2060 | SP2060 V1.3 Supplementary Manual - Page 1
    been added to the DME Designer, enabling you to back up the SP2060 data to a computer and to restore the data on multiple SP2060 units. Refer to the DME Designer Owner's Manual for details. • The following speaker processor libraries have been added. IS1112 IS1112+IF2108 (Settings for combination of
  • Yamaha SP2060 | SP2060 V1.3 Supplementary Manual - Page 2
    on the screen. NOTE • If you have specified a password, a password input display will appear (page 35 of the Owner's Manual). USER LOCK ON Protecting a scene (page 32 of the Owner's Manual) Follow the steps below to protect a scene: If the password has been set for the User Lock function, you must
  • 1
  • 2

ES
EN
DE
FR
This supplemental manual describes functions that have been newly added or modified for SP2060
firmware version 1.3. Please read this manual along with the SP2060 Owner’s Manual and the DME
Designer Owner’s Manual.
The User Lock function enables you not only to lock the
entire panel operation but also to lock each key.
If a password has been set for the User Lock function, the
same password now applies to switching scene protection on
or off.
The SP2060 Backup function has been added to the DME
Designer, enabling you to back up the SP2060 data to a com-
puter and to restore the data on multiple SP2060 units. Refer
to the DME Designer Owner’s Manual for details.
The following speaker processor libraries have been added.
IS1112
IS1112+IF2108 (Settings for combination of IS1112 and
IF2108)
IS1112+IF2208 (Settings for combination of IS1112 and
IF2208)
Parameter settings can be “locked” temporarily to prevent acci-
dental mis-operation. This function is useful to avoid uninten-
tional operations or to prevent others from operating the panel
controls. You can specify a password for User Lock.
You can specify one or more of the following keys to lock the pa-
rameter setting assigned to that key.
[LEVEL] key, [DELAY] key, [EQ] key, [ROUTING] key, [X-
OVER] key, [LIMITER] key, [SCENE] key, [UTILITY] key
1.
Press the [UTILITY] key to select the Utility dis-
play.
The most recently used Utility display will appear.
2.
Press the [UTILITY], [NEXT] or [BACK] key
repeatedly until the User Lock page appears.
3.
Press the [NEXT] key twice to display the User
Lock Detail page.
The front panel keys in the range from the [LEVEL] key to
the [UTILITY] key (but excluding the [MUTE] key) will
light up (User Lock On) or flash (User Lock Off), indicat-
ing which keys are locked.
4.
Press the desired front panel keys (in the range
from the [LEVEL] keys to the [UTILITY] key) to
turn User Lock on or off for the corresponding
parameter setting.
5.
Press the [BACK] key twice to return to the User
Lock page.
SP2060 V1.3 Supplemental Manual
NOTE
• You can mute or unmute, or cancel User Lock even if the User
Lock function is turned on.
• The User Lock function is effective only for the panel controls on
the SP2060, and does not affect any control signals from the
DME Designer or other external devices.
Primary modifications
User Lock
(page 34 in the Owner’s Manual)
USER LOCK
OFF
USER LOCK DETAIL
SET BY KEYS
->