Zenith SL-5525-WH User Guide - Page 1

Zenith SL-5525-WH - Heath - Quartz Motion-Sensing Light Manual

Page 1 highlights

Motion Sensing Halogen Fixture OPERATION Mode: Test Auto Manual On-Time 5 Seconds 1, 5, or 10 Min Until Dawn* Works: Day Night xx x x * resets to Auto Mode at dawn. Note: When first turned on wait about 1 1/2 minutes for the circuitry to calibrate. Model SL-5525 Features • Turns on lighting when motion is detected. • Automatically turns lighting off. • Photocell keeps the lighting off during daylight hours. • LED indicates motion was sensed (day or night). This package includes: TEST Put the ON-TIME switch on the bottom of the sensor in the TEST position. ON-TIME 10 5 1 TEST AUTO Put the ON-TIME switch in the 1, 5, or 10 minute position. ON-TIME 10 5 1 TEST Plastic Hanger 6 Screws (3 sizes included) Gasket MANUAL MODE Manual mode only works at night because daylight returns the sensor to AUTO. 3 Wire Connectors 1 Halogen Lamp Sensor Mounting Strap Light Control Flip the light switch off for one second then back on to toggle between AUTO and MANUAL MODE. 1 Second OFF then... Manual mode works only with the ON-TIME switch in the 1, 5, or 10 position. ... back on. Mounting Bolt Light Shield Rubber Plug Requirements • The light control requires 120-volts AC. • If you want to use Manual Mode, the control must be wired through a switch. • Some codes require installation by a qualified electrician. • This product is intended for use with the enclosed gasket and with a junction box marked for use in wet locations. Mode Switch Summary TEST Move ON-TIME Switch to 1, 5, or 10 minutes AUTO MANUAL MODE Flip light switch off for one second then back on* * If you get confused while switching modes, turn the power off for one minute, then back on. After the calibration time the control will be in the AUTO mode. © 2007 HeathCo LLC 595-5295-12

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

© 2007 HeathCo LLC
595-5295-12
1 Halogen
Lamp
Sensor
Light Control
Requirements
• The light control requires 120-volts AC.
• If you want to use Manual Mode, the control must be
wired through a switch.
• Some codes require installation by a qualified
electrician.
• This product is intended for use with the enclosed
gasket and with a junction box marked for use in wet
locations.
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).
Motion Sensing
Halogen Fixture
Model SL-5525
3 Wire
Connectors
6 Screws
(3 sizes included)
Gasket
Mounting Bolt
Mounting Strap
OPERATION
* resets to Auto Mode at dawn.
MANUAL MODE
ON-TIME
10 5 1
TEST
10 5 1
TEST
ON-TIME
TEST
AUTO
Move ON-TIME Switch to
1, 5, or 10 minutes
Mode Switch Summary
Flip light switch
off for one second
then back on*
MANUAL MODE
AUTO
TEST
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.
Note: When first turned on wait about 1
1
/
2
minutes for
the circuitry to calibrate.
Light Shield
Plastic Hanger
Rubber Plug
Put the ON-TIME switch on the bottom
of the sensor in the TEST position.
Put the ON-TIME switch in the 1, 5,
or 10 minute position.
Manual mode only works at night
because daylight returns the sen-
sor to AUTO.
Flip the light switch off for one sec-
ond then back on to toggle between
AUTO and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 10
position.
This package includes:
Mode:
On-Time
Works:
Day Night
Test
5 Seconds
x
x
Auto
1, 5, or 10 Min
x
Manual
Until Dawn*
x
... back on.
1 Second OFF
then
...