ZyXEL PLA-407 User Guide - Page 72
Compatibility Diagrams
View all ZyXEL PLA-407 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 72 highlights
Chapter 8 PLA Compatibility • For PLA v1 models (for example, PLA-400, PLA-401, PLA-470, PLA-491 and so on) upgrade the firmware version from 1.4.5 to at least version 3.0.5. Refer to the PLA-4XX series User's Guide for instructions on how to do this. • For PLA v2 models (for example, PLA400 v2, PLA402 v2, PLA401 v2, PLA470 v2 and so on) make sure the firmware version is at least version 3.0.5. • For PLA v3 models (for example, PLA401 v3 and PLA402 v3) the factory default firmware version is 3.3.4. Note: You cannot downgrade the PLA-407's firmware to a version earlier than 4.0.1. 8.3 Compatibility Diagrams Use Configuration Utility version 3.3.4 to manage PLA v2 and PLA v1 models with firmware versions 3.0.5. This diagram below shows a Powerline network where two PLAs have an earlier firmware (1.4.5) that cannot be managed by the 3.3.4 Configuration Utility. You should upgrade the firmware of these PLAs. Figure 51 Wrong Firmware in a Powerline Network 1.4.5 4.0.1 1.4.5 4.0.1 3.3.4 3.0.5 72 PLA-407 User's Guide