3Com 3C16476BS-US User Guide - Page 14
Aufstellen des Switch, Rack-Mounting or Free-Standing, Using the Mounting Kit
UPC - 662705490274
View all 3Com 3C16476BS-US manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 14 highlights
14 CHAPTER 2: INSTALLING THE SWITCH mends that you provide a minimum of 25 mm or 1 in. clearance). ■ The air is as free of dust as possible. ■ Temperature operating limits are not likely to be exceeded. It is recommended that the unit is installed in a clean, air conditioned environment. It is always good practice to wear an anti-static wrist strap when installing network equipment, connected to a ground point. If one is not available, try to keep in contact with a grounded rack and avoid touching the unit's ports and connectors, if possible. Static discharge can cause reliability problems in your equipment. Aufstellen des Switch Bei der Entscheidung wo Sie den Switch positionieren, stellen Sie sicher das: ■ Der Switch zugänglich ist und die Kabel leicht angeschlossen werden können. ■ Die Kabel nicht in der nähe von elektrischen Störquellen befinden. Das schließt Aufzugsschächte, Mikrowellen und Klimaanlagen ein. Elektromagnetische Felder können die Signale in den Kupferleitungen stören, und Fehler verursachen, was die Verlangsamung Ihres Netzwerkes zur Folge haben kann. ■ Weder Wasser noch Feuchtigkeit in das Gehäuse eindringen kann. ■ Die Luftzirkulation um den Switch und durch die Öffnungen des Gehäuses nicht behindert wird. 3Com empfiehlt das Sie 25mm (1 Inch) Zwischenraum sicherstellen. ■ Die Luft so frei wie möglich von Staub ist. ■ Es unwahrscheinlich ist das die Betriebstemperatur überschritten wird. 3Com empfiehlt das Sie den Switch in einer sauberen, klimatisierten Umgebung installieren. Rack-Mounting or Free-Standing The unit can be mounted in a 19-inch equipment rack using the supplied mounting kit, (see "Using the Mounting Kit" on page 14), or it can be free-standing. Do not place objects on top of the unit or stack. CAUTION: If installing the Switch in a free-standing stack of different size Baseline or SuperStack® 3 units, the smaller units must be installed above the larger ones. Do not have a free-standing stack of more than six units. Using the Mounting Kit The Switch is supplied with two mounting brackets and four screws. These are used for rack mounting the unit. When mounting the unit, take note of the guidelines given in "Positioning the Switch" on page 13. The Switch is 1U (1.75 in.) high and will fit in a standard 19-inch rack. CAUTION: Before continuing, disconnect all cables from the unit. Remove the self-adhesive pads from the underside of unit, if already fitted.