3Com 3CR17250-91 Data Sheet - Page 7

Specifications, Redundant Power System

Page 7 highlights

3Com® Switch 5500G 10/100/1000 Family SPECIFICATIONS (CONTINUED) Configuration file for backup and restore, stored in non-volatile memory; multiple configuration files available Backup and restore of software images Network Time Protocol (NTP) DHCP Relay and UDP Helper System file transfer mechanisms: Xmodem, FTP, Trivial FTP (TFTP), Secure FTP (SFTP) 3Com management applications: • 3Com Enterprise Management Suite for flexible, extensible management in advanced enterprise IT environments • 3Com Network Director for comprehensive, turn-key network management for the enterprise • 3Com Network Supervisor for basic, turn-key network management for mid-market businesses • 3Com Network Access Manager for IEEE 802.1X and RADA integration with IAS/Active Directory • 3Com Switch Manager for virtual clustering support across 3Com switch families DIMENSIONS Height: 43.6 mm (1.7 in or 1U) Width: 440 mm (17.3 in) Depth: 450 mm (17.7 in) Weight: varies, depending on PSU installed POWER SUPPLY Mode support: AC-only, AC and DC, DC-only operation Built-in DC power stage for direct connection to -48 V supply Field-replaceable power supply AC Line Frequency: 50/60 Hz Input Voltage: 90-240 VAC AC current rating: 3.0A max. (PWR models: 8.0A max.) DC current rating: 5.5A max. (PWR 24-port: 12.0A; PWR 48-port: 19.5A; max.) Non-PWR models are field-upgradeable to PoE support with installation of PoEenabled power supply Power consumption (max) 24-port non-PWR: 150 W 48-port non-PWR: 210 W 24-port PWR: 150 W, plus up to 300 W for PoE 48-port PWR: 210 W, plus up to 300 W for PoE 24-port SFP: 150 W ENVIRONMENTAL Operating temperature: 0° to 40°C (32° to 104°F) Operating altitude: 0 to 4,572 meters (0 to 15,000 feet) Storage temperature: -40° to 70°C (-40° to 158°F) Humidity (operating and storage): 10% to 95% non-condensing Standard: EN 60068 (IEC 68) Sound pressure level (dBA): • 48-port: 54.5 decibels • 48-port PWR: 53.0 decibels • 24-port: 52.6 decibels • 24-port PWR: 54.1 decibels • 24-port SFP: 57.4 decibels Heat dissipation (max) 24-port non-PWR: 515 BTU/hour 48-port non-PWR: 720 BTU/hour 24-port PWR: 515 BTU/hour; excludes heat from PoE 48-port PWR: 720 BTU/hour; excludes heat from PoE 24-port SFP: 515 BTU/hour RELIABILITY (MTBF @ 25°C) 48-port: 25 years (219,000 hours) 48-port PWR: 23 years (201,000 hours) 24-port: 34 years (298,000 hours) 24-port PWR: 31 years (272,000 hours) 24-port SFP: 29 years (256,000 hours) INDUSTRY STANDARDS SUPPORTED Ethernet Protocols IEEE 802.1D (STP) IEEE 802.1p (CoS) IEEE 802.1Q (VLANs) IEEE 802.1s (MSTP) IEEE 802.1v (Protocol VLANs) IEEE 802.1w (RSTP) IEEE 802.1X (Security) IEEE 802.3 (Ethernet) IEEE 802.3ab (1000BASE-T) IEEE 802.3ad (Link Aggregation) IEEE 802.3ae (10G Ethernet) IEEE 802.3af (Power over Ethernet) IEEE 802.3i (10BASE-T) IEEE 802.3u (100BASE-TX/-FX) IEEE 802.3x (Flow Control) IEEE 802.3z (1000BASE-X) Management, including MIBs Supported RFC 768 (UDP) RFC 783 (TFTP) RFC 791 (IP) RFC 792 (ICMP) RFC 793 (TCP) RFC 826 (ARP) RFC 1058 (Routing Information Protocol) RFC 1112 (IP Multicasting) RFC 1157 (SNMP) RFC 1213 (MIB II) RFC 1253 (OSPF v2) RFC 1583 (OSPF v2) RFC 1587 (OSPF NSSA Option) RFC 1724 (RIP v2 MIB Extension) RFC 1757 (RMON) RFC 1812 (Requirements for IPv4 Routers) RFC 1850 (OSPF v2) RFC 1901 (Community Based SNMP v2) RFC 1902 (SMI for SNMP v2 ) RFC 1903 (SNMP v2 Text Conventions) RFC 1904 (SNMP v2 Conformance) RFC 1905 (SNMP v2 Protocol Operations) RFC 1906 (SNMP v2 Transport Mappings) RFC 1907 (SNMP v2c) RFC 1908 (SNMP v1/2 Coexistence) RFC 2021 (RMON II Probe Config) RFC 2154 (OSPF Digital Signatures) RFC 2233 (Interfaces) RFC 2236 (IGMP v2) RFC 2328 (OSPF v2) RFC 2338 (VRRP) RFC 2362 (PIM-SM) RFC 2570 (SNMP v3 Framework) RFC 2571 (FrameWork) RFC 2571-2575 (SNMP) RFC 2576 (SNMP v1/2/3 Coexistence) RFC 2578 (SMI v2 Structure) RFC 2579 (SMI v2 Text Conventions) RFC 2580 (SMI v2 Conformance) RFC 2613 (Remote Network Monitoring MIB Extensions) RFC 2618 (RADIUS Authentication Client) RFC 2620 (RADIUS Accounting Client) RFC 2644 (Restricted Directed Broadcast) RFC 2665 (Pause Control) RFC 2674 (VLAN MIB Extension) RFC 2819 (RMON groups Alarm, Event, History and Statistics only) RFC 2819 (RMON) RFC 3410 (Management Framework) RFC 3414 (SNMP v3 USM) RFC 3415 (SNMP v3 VACM) RFC 3416 (SNMP Protocol Operations v2) RFC 3417 (SNMP Transport Mappings) SNMP v3 and RMON RFC support EMISSIONS / AGENCY APPROVALS CISPR 22 Class A FCC Part 15 Class A EN 55022 1998 Class A EN 61000-3-2 2000, 61000-3-3 ICES-003 Class A VCCI Class A IMMUNITY EN 55024 SAFETY AGENCY CERTIFICATIONS UL 60950 IEC 60950-1 EN 60950-1 CAN/CSA-C22.2 No. 60950-1-03 WARRANTY AND OTHER SERVICES Limited Lifetime Hardware Warranty, including fans and power supply Limited Software Warranty for 90 days Advance Hardware Replacement with Next Business Day shipment in most regions Limited Lifetime software updates 90 days of telephone technical support Refer to www.3com.com/warranty for details. REDUNDANT POWER SYSTEM 3Com has tested and qualified a Redundant Power System (RPS) solution designed for the Switch 5500G family by Eaton Powerware Corporation, a leading global provider of power quality and management solutions. The Powerware DC RPS systems come in either 3RU or 6RU form-factors, delivering up to 9,000W of DC power to a stack of Switch 5500G units. The 3RU RPS unit houses up to three hot-swappable rectifiers supplying up to 4,500W of power that supports up to eight separately-fused DC outputs, while the 6RU unit can house up to six hot-swappable rectifiers provisioning a total of 9,000W. The RPS supports SNMP management, including MIB II, which is easily accessible through the built-in RJ-45 or serial port. It is fully compatible with the IEEE 802.3af Power over Ethernet standard, providing supplemental power for the 3Com Switch 5500G PWR models. With this RPS, all 384 10/100/1000 ports on a stack of eight Switch 5500G PWR 48-port units can receive the industry standard 15.4W of power per port, with N+1 power redundancy. The RPS ships with the power input fully configured and can be connected to a UPS with battery backup. For more details, refer to www.3com.com/rps. 7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

3Com
®
Switch 5500G 10/100/1000 Family
7
Configuration file for backup and
restore, stored in non-volatile
memory; multiple configuration files
available
Backup and restore of software images
Network Time Protocol (NTP)
DHCP Relay and UDP Helper
System file transfer mechanisms:
Xmodem, FTP,Trivial FTP (TFTP),
Secure FTP (SFTP)
3Com management applications:
• 3Com Enterprise Management Suite
for flexible, extensible management
in advanced enterprise IT environ-
ments
• 3Com Network Director for
comprehensive, turn-key network
management for the enterprise
• 3Com Network Supervisor for basic,
turn-key network management for
mid-market businesses
• 3Com Network Access Manager for
IEEE 802.1X and RADA integration
with IAS/Active Directory
• 3Com Switch Manager for virtual
clustering support across 3Com
switch families
DIMENSIONS
Height: 43.6 mm (1.7 in or 1U)
Width: 440 mm (17.3 in)
Depth: 450 mm (17.7 in)
Weight: varies, depending on PSU
installed
POWER SUPPLY
Mode support: AC-only, AC and DC,
DC-only operation
Built-in DC power stage for direct
connection to -48 V supply
Field-replaceable power supply
AC Line Frequency: 50/60 Hz
Input Voltage: 90-240 VAC
AC current rating: 3.0A max.
(PWR models: 8.0A max.)
DC current rating: 5.5A max.
(PWR 24-port: 12.0A;
PWR 48-port: 19.5A; max.)
Non-PWR models are field-upgradeable
to PoE support with installation of PoE-
enabled power supply
Power consumption
(max)
24-port non-PWR: 150 W
48-port non-PWR: 210 W
24-port PWR: 150 W, plus up to
300 W for PoE
48-port PWR: 210 W, plus up to
300 W for PoE
24-port SFP: 150 W
ENVIRONMENTAL
Operating temperature: 0° to 40°C
(32° to 104°F)
Operating altitude: 0 to 4,572 meters
(0 to 15,000 feet)
Storage temperature: -40° to 70°C
(-40° to 158°F)
Humidity (operating and storage):
10% to 95% non-condensing
Standard: EN 60068 (IEC 68)
Sound pressure level (dBA):
• 48-port: 54.5 decibels
• 48-port PWR: 53.0 decibels
• 24-port: 52.6 decibels
• 24-port PWR: 54.1 decibels
• 24-port SFP: 57.4 decibels
Heat dissipation
(max)
24-port non-PWR: 515 BTU/hour
48-port non-PWR: 720 BTU/hour
24-port PWR: 515 BTU/hour; excludes
heat from PoE
48-port PWR: 720 BTU/hour; excludes
heat from PoE
24-port SFP: 515 BTU/hour
RELIABILITY
(MTBF @ 25°C)
48-port: 25 years (219,000 hours)
48-port PWR: 23 years (201,000 hours)
24-port: 34 years (298,000 hours)
24-port PWR: 31 years (272,000 hours)
24-port SFP: 29 years (256,000 hours)
INDUSTRY STANDARDS
SUPPORTED
Ethernet Protocols
IEEE 802.1D (STP)
IEEE 802.1p (CoS)
IEEE 802.1Q (VLANs)
IEEE 802.1s (MSTP)
IEEE 802.1v (Protocol VLANs)
IEEE 802.1w (RSTP)
IEEE 802.1X (Security)
IEEE 802.3 (Ethernet)
IEEE 802.3ab (1000BASE-T)
IEEE 802.3ad (Link Aggregation)
IEEE 802.3ae (10G Ethernet)
IEEE 802.3af (Power over Ethernet)
IEEE 802.3i (10BASE-T)
IEEE 802.3u (100BASE-TX/-FX)
IEEE 802.3x (Flow Control)
IEEE 802.3z (1000BASE-X)
Management, including MIBs
Supported
RFC 768 (UDP)
RFC 783 (TFTP)
RFC 791 (IP)
RFC 792 (ICMP)
RFC 793 (TCP)
RFC 826 (ARP)
RFC 1058 (Routing Information
Protocol)
RFC 1112 (IP Multicasting)
RFC 1157 (SNMP)
RFC 1213 (MIB II)
RFC 1253 (OSPF v2)
RFC 1583 (OSPF v2)
RFC 1587 (OSPF NSSA Option)
RFC 1724 (RIP v2 MIB Extension)
RFC 1757 (RMON)
RFC 1812 (Requirements for IPv4
Routers)
RFC 1850 (OSPF v2)
RFC 1901 (Community Based SNMP v2)
RFC 1902 (SMI for SNMP v2 )
RFC 1903 (SNMP v2 Text Conventions)
RFC 1904 (SNMP v2 Conformance)
RFC 1905 (SNMP v2 Protocol
Operations)
RFC 1906 (SNMP v2 Transport
Mappings)
RFC 1907 (SNMP v2c)
RFC 1908 (SNMP v1/2 Coexistence)
RFC 2021 (RMON II Probe Config)
RFC 2154 (OSPF Digital Signatures)
RFC 2233 (Interfaces)
RFC 2236 (IGMP v2)
RFC 2328 (OSPF v2)
RFC 2338 (VRRP)
RFC 2362 (PIM-SM)
RFC 2570 (SNMP v3 Framework)
RFC 2571 (FrameWork)
RFC 2571-2575 (SNMP)
RFC 2576 (SNMP v1/2/3 Coexistence)
RFC 2578 (SMI v2 Structure)
RFC 2579 (SMI v2 Text Conventions)
RFC 2580 (SMI v2 Conformance)
RFC 2613 (Remote Network
Monitoring MIB Extensions)
RFC 2618 (RADIUS Authentication
Client)
RFC 2620 (RADIUS Accounting Client)
RFC 2644 (Restricted Directed
Broadcast)
RFC 2665 (Pause Control)
RFC 2674 (VLAN MIB Extension)
RFC 2819 (RMON groups Alarm,
Event, History and Statistics only)
RFC 2819 (RMON)
RFC 3410 (Management Framework)
RFC 3414 (SNMP v3 USM)
RFC 3415 (SNMP v3VACM)
RFC 3416 (SNMP Protocol
Operations v2)
RFC 3417 (SNMP Transport Mappings)
SNMP v3 and RMON RFC support
EMISSIONS / AGENCY APPROVALS
CISPR 22 Class A
FCC Part 15 Class A
EN 55022 1998 Class A
EN 61000-3-2 2000, 61000-3-3
ICES-003 Class A
VCCI Class A
IMMUNITY
EN 55024
SAFETY AGENCY CERTIFICATIONS
UL 60950
IEC 60950-1
EN 60950-1
CAN/CSA-C22.2 No. 60950-1-03
WARRANTY AND OTHER SERVICES
Limited Lifetime Hardware Warranty,
including fans and power supply
Limited Software Warranty for 90 days
Advance Hardware Replacement
with Next Business Day shipment in
most regions
Limited Lifetime software updates
90 days of telephone technical support
Refer to
www.3com.com/warranty
for details.
SPECIFICATIONS
(CONTINUED)
3Com has tested and qualified a Redundant Power System (RPS) solution
designed for the Switch 5500G family by Eaton Powerware Corporation,
a leading global provider of power quality and management solutions.
The Powerware DC RPS systems come in either 3RU or 6RU form-factors,
delivering up to 9,000W of DC power to a stack of Switch 5500G units.
The 3RU RPS unit houses up to three hot-swappable rectifiers supplying
up to 4,500W of power that supports up to eight separately-fused DC
outputs, while the 6RU unit can house up to six hot-swappable rectifiers
provisioning a total of 9,000W.
The RPS supports SNMP management, including MIB II, which is easily
accessible through the built-in RJ-45 or serial port. It is fully compatible
with the IEEE 802.3af Power over Ethernet standard, providing supple-
mental power for the 3Com Switch 5500G PWR models.
With this RPS, all 384 10/100/1000 ports on a stack of eight Switch
5500G PWR 48-port units can receive the industry standard 15.4W
of power per port, with N+1 power redundancy.
The RPS ships with the power input fully configured and can be
connected to a UPS with battery backup. For more details, refer to
www.3com.com/rps
.
REDUNDANT POWER SYSTEM