Table 1: Aen Error Messages, Soft_reset, Aen 002h, Aen_degraded_unit, Aen_controller_error
View all 3Ware 3W-7410 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 109 highlights
Screen display messages Table 1: AEN Error Messages Message AEN_UNIT_NOT_ZEROED AEN_UDMA_DOWNGRADE AEN_SECTOR_REPAIR AEN_SBUF_FAIL AEN_LOST_CACHED_WRITE AEN_DRIVE_ECC_ERROR AEN_DCB_XSUM_ERROR AEN_DCB_BAD_VERSION AEN_VERIFY_STARTED AEN_VERIFY_FAILED AEN_VERIFY_DONE AEN_SECTOR_OVERWRITE AEN_RBLD_SOURCE_ERROR AEN_DRIVE_NOT_SUPPORTED AEN_QUEUE_FULL Value 02Fh 021h 023h 024h 025h 026h 027h 028h 029h 02Ah 02Bh 02Ch 02Dh 030h 0FFh AEN 001h SOFT_RESET The ATA RAID controller has detected a soft reset from the device driver. Soft resets are normal at driver load and unload time. If the ATA RAID controller fails to respond to the device driver within a reasonable amount of time, the device driver may issue a soft reset to the ATA RAID controller and retry the command packet. AEN 002h AEN_DEGRADED_UNIT An error has been encountered and the array is operating in degraded (nonredundant) mode.The user should replace the bad drive as soon as possible and initiate a rebuild. AEN 003h AEN_CONTROLLER_ERROR The ATA RAID controller has encountered an internal error. Please contact 3ware customer support. www.3ware.com 101