AEG HK614010BB Product Manual - Page 6

Assembly

Page 6 highlights

6 Installation instructions • Use the correct mains cable of type H05BB-F Tmax 90°C (or higher) for a single phase or two phase connection. • Replace the damaged mains cable with a special cable (type H05BB-F Tmax 90°C; or higher). Speak your local Service Centre. The appliance must have the electrical installation which lets you disconnect the appliance from the mains at all poles with a contact opening width of minimum 3 mm. You must have correct devices to isolate: line protecting cut-outs, fuses (screw type fuses removed from the holder), earth leakage trips and contactors. Assembly min. 50mm min. 500mm min. 50mm R 5mm 600mm = 490+1mm 560+1mm = min. 20 mm min. 25 mm min. 28 mm

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

Use the correct mains cable of type H05BB-F Tmax 90°C (or higher) for a single phase or
two phase connection.
Replace the damaged mains cable with a special cable (type H05BB-F Tmax 90°C; or
higher). Speak your local Service Centre.
The appliance must have the electrical installation which lets you disconnect the appliance
from the mains at all poles with a contact opening width of minimum 3 mm.
You must have correct devices to isolate: line protecting cut-outs, fuses (screw type fuses
removed from the holder), earth leakage trips and contactors.
Assembly
min.
50mm
min.
50mm
min.
500mm
=
=
490
+1
mm
560
+1
mm
600
mm
R 5
mm
min.
25 mm
min.
20 mm
min.
28 mm
6
Installation instructions