AEG T35850 Product Manual - Page 20
Door reversal, Special accessories
![]() |
View all AEG T35850 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 20 highlights
20 Installation The wires in the mains lead are coloured in ac- cordance with the following code: 4 1 Blue - Neutral 2 cord clamp 3 Brown - Live 4 Green and Yellow - Earth The wire coloured green and yellow must be con- nected to the terminal marked with the letter «E» or by the earth symbol or coloured green and 3 yellow. The wire coloured blue must be connected to the 1 2 terminal «N» or coloured black. The wire coloured brown must be connected to the terminal marked «L» or coloured red. Upon completion there must be no cut, or stray strands of wire present and the cord clamp must be secure over the outer sheath. WARNING! A cut off plug inserted into a 13 amp socket is a serious safety (shock) hazard. Ensure that the cut off plug is disposed of safely. WARNING! The plug must be accessible after installing the machine. Permanent connection In the case of permanent connection it is necessary that you install a double pole switch between the appliance and the electricity supply (mains), with a minimum gap of 3 mm between the switch contacts and of a type suitable for the required load in compliance with the current electrical regulations. The switch must not break the yellow and green earth cable at any point. Door reversal To make it easier to load or unload the laundry the door can be reversed. This operation must be carried out by qualified personnel. Please contact the nearest Service Centre. Special accessories Stacking kit