ASRock B550M-ITX/ac User Manual - Page 59

Infinity Fabric Frequency and Dividers

Page 59 highlights

B550M-ITX/ac Infinity Fabric Frequency and Dividers AMD Overclocking Setup Set Infinity Fabric frequency (FCLK). Auto: FCLK = MCLK. Manual: FCLK must be less than or equal to MCLK for best performance in most cases. Latency penalties are incurred if FCLK and MCLK are mismatched, but sufficiently high MCLK can negate or overcome this penalty. DRAM Timing Configuration External Voltage Settings and Load-line Calibration CPU Vcore Voltage Input voltage for the processor by the external voltage refulator. CPU Load-Line Calibration CPU Load-Line Calibration helps prevent CPU voltage droop when the system is under heavy loading. VDDCR_SOC Voltage Configure the voltage for the VID-requested VDDCR_SOC supply level. VDDCR_SOC Load-Line Calibration CPU VDDCR_SOC Load-Line Calibration helps prevent VDDCR_SOC voltage droop when the system is under heavy loading.U VPPM Configure the voltage for the VPPM. VDDP Configure the voltage for the VDDP. +1.8 Voltage Configure the voltage for the +1.8V. DRAM Voltage Configure the voltage for the DRAM. Chipset 1.05V Voltage Configure the voltage for the chipset 1.05V voltage. Save User Default Type a profile name and press enter to save your settings as user default. 53 English

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80

English
53
B550M-ITX/ac
Infinity Fabric Frequency and Dividers
AMD Overclocking Setup Set Infinity Fabric frequency (FCLK). Auto: FCLK = MCLK.
Manual: FCLK must be less than or equal to MCLK for best performance in most cases.
Latency penalties are incurred if FCLK and MCLK are mismatched, but sufficiently high
MCLK can negate or overcome this penalty.
DRAM Timing Configuration
External Voltage Settings and Load-line Calibration
CPU Vcore Voltage
Input voltage for the processor by the external voltage refulator.
CPU Load-Line Calibration
CPU Load-Line Calibration helps prevent CPU voltage droop when the system is under
heavy loading.
VDDCR_SOC Voltage
Configure the voltage for the VID-requested VDDCR_SOC supply level.
VDDCR_SOC Load-Line Calibration
CPU VDDCR_SOC Load-Line Calibration helps prevent VDDCR_SOC voltage droop when
the system is under heavy loading.U
VPPM
Configure the voltage for the VPPM.
VDDP
Configure the voltage for the VDDP.
+1.8 Voltage
Configure the voltage for the +1.8V
.
DRAM Voltage
Configure the voltage for the DRAM
.
Chipset 1.05V Voltage
Configure the voltage for the chipset 1.05V voltage.
Save User Default
Type a profile name and press enter to save your settings as user default.