ASRock H370 Pro4 User Manual - Page 68

Control Slew Rate, Clock Slew Rate

Page 68 highlights

DQ ODT Driving Adjust ODT Driving for better signal. Default is 60. DQ Driving Adjust DQ Driving for better signal. Default is 26. Command Driving Adjust Command Driving for better signal. Default is 20. Control Driving Adjust Control Driving for better signal. Default is 20. Clock Driving Adjust Clock Driving for better signal. Default is 26. DQ Slew Rate Adjust DQ Slew Rate for better signal. Default is 59. Command Slew Rate Adjust Command Slew Rate for better signal. Default is 53 for IN. 89 for 2N. Control Slew Rate Adjust Control Slew Rate for better signal. Default is 53. Clock Slew Rate Adjust Clock Slew Rate for better signal. Default is 53. MRS Setting MRS TCL Configure the tCL for Memory MRS MR0. MRS tWRtRTP Configure the tWRtRTP for Memory MRS MR0. MRS tCWL Configure the tCWL for Memory MRS MR2. 62 English

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96

62
English
DQ ODT Driving
Adjust ODT Driving for better signal. Default is 60.
DQ Driving
Adjust DQ Driving for better signal. Default is 26.
Command Driving
Adjust Command Driving for better signal. Default is 20.
Control Driving
Adjust Control Driving for better signal. Default is 20.
Clock Driving
Adjust Clock Driving for better signal. Default is 26.
DQ Slew Rate
Adjust DQ Slew Rate for better signal. Default is 59.
Command Slew Rate
Adjust Command Slew Rate for better signal. Default is 53 for IN. 89 for 2N.
Control Slew Rate
Adjust Control Slew Rate for better signal. Default is 53.
Clock Slew Rate
Adjust Clock Slew Rate for better signal. Default is 53.
MRS Setting
MRS TCL
Configure the tCL for Memory MRS MR0.
MRS tWRtRTP
Configure the tWRtRTP for Memory MRS MR0.
MRS tCWL
Configure the tCWL for Memory MRS MR2.