ASRock K7S8XE User Manual - Page 14

FID Jumpers

Page 14 highlights

FID Jumpers (FID0, FID1, FID2, FID3, FID4) (see p.7 item 33) 1 FID0 1 FID1 1 FID2 1 FID3 1 FID4 Note: The set of FID jumpers are only for advanced users to adjust the multiplier of CPU. Please follow the table below to adjust the multiplier of CPU. However, the system will work well without the adjustment of multiplier. You do not have to adjust the multiplier for normal usage. Multiplier 5x 5.5x 6x 6.5x 7x 7.5x 8x 8.5x 9x 9.5x 10x 10.5x 11x 11.5x 12x 12.5x 13x 13.5x 14x 15x 16x 16.5x 17x 18x 19x 20x 21x 22x 23x 24x FID0 2-3 1-2 2-3 1-2 2-3 1-2 2-3 1-2 2-3 1-2 2-3 1-2 2-3 1-2 2-3 1-2 2-3 1-2 2-3 2-3 2-3 1-2 2-3 1-2 1-2 1-2 1-2 1-2 2-3 1-2 FID1 2-3 2-3 1-2 1-2 2-3 2-3 1-2 1-2 2-3 2-3 1-2 1-2 2-3 2-3 1-2 1-2 2-3 2-3 1-2 2-3 1-2 1-2 2-3 2-3 2-3 1-2 1-2 2-3 1-2 1-2 FID2 1-2 1-2 1-2 1-2 2-3 2-3 2-3 2-3 1-2 1-2 1-2 1-2 2-3 2-3 2-3 2-3 1-2 1-2 1-2 2-3 2-3 2-3 1-2 1-2 2-3 2-3 1-2 2-3 1-2 1-2 FID3 2-3 2-3 2-3 2-3 1-2 1-2 1-2 1-2 1-2 1-2 1-2 1-2 2-3 2-3 2-3 2-3 2-3 2-3 2-3 1-2 1-2 1-2 1-2 1-2 2-3 2-3 2-3 1-2 1-2 1-2 FID4 2-3 2-3 2-3 2-3 2-3 2-3 2-3 2-3 2-3 2-3 2-3 2-3 2-3 2-3 2-3 2-3 1-2 1-2 1-2 1-2 1-2 1-2 1-2 1-2 1-2 1-2 1-2 1-2 1-2 1-2 For example, "Athlon XP 2000+" is an 1666MHz CPU: 12.5 (Multiplier) X 133MHz (External frequency) = 1666MHz FID jumpers setting: 1 FID0 1 FID1 1 FID2 1 FID3 1 FID4 The jumper caps are not provided by ASRock. Please understand that ASRock does not guarantee and support the adjustment of multiplier. These jumpers setting may not apply to all multiplier-locked or even some unlocked AMD CPU. Frequencies other than the recommended CPU bus frequencies may cause the instability of the system or damage the CPU. 14

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31

14
FID Jumpers
(FID0, FID1, FID2, FID3, FID4)
(see p.7 item 33)
Note:
The set of FID jumpers are only for advanced users to adjust the multiplier of CPU.
Please follow the table below to adjust the multiplier of CPU. However, the system will
work well without the adjustment of multiplier. You do not have to adjust the multiplier
for normal usage.
Multiplier
FID0
FID1
FID2
FID3
FID4
5x
2-3
2-3
1-2
2-3
2-3
5.5x
1-2
2-3
1-2
2-3
2-3
6x
2-3
1-2
1-2
2-3
2-3
6.5x
1-2
1-2
1-2
2-3
2-3
7x
2-3
2-3
2-3
1-2
2-3
7.5x
1-2
2-3
2-3
1-2
2-3
8x
2-3
1-2
2-3
1-2
2-3
8.5x
1-2
1-2
2-3
1-2
2-3
9x
2-3
2-3
1-2
1-2
2-3
9.5x
1-2
2-3
1-2
1-2
2-3
10x
2-3
1-2
1-2
1-2
2-3
10.5x
1-2
1-2
1-2
1-2
2-3
11x
2-3
2-3
2-3
2-3
2-3
11.5x
1-2
2-3
2-3
2-3
2-3
12x
2-3
1-2
2-3
2-3
2-3
12.5x
1-2
1-2
2-3
2-3
2-3
13x
2-3
2-3
1-2
2-3
1-2
13.5x
1-2
2-3
1-2
2-3
1-2
14x
2-3
1-2
1-2
2-3
1-2
15x
2-3
2-3
2-3
1-2
1-2
16x
2-3
1-2
2-3
1-2
1-2
16.5x
1-2
1-2
2-3
1-2
1-2
17x
2-3
2-3
1-2
1-2
1-2
18x
1-2
2-3
1-2
1-2
1-2
19x
1-2
2-3
2-3
2-3
1-2
20x
1-2
1-2
2-3
2-3
1-2
21x
1-2
1-2
1-2
2-3
1-2
22x
1-2
2-3
2-3
1-2
1-2
23x
2-3
1-2
1-2
1-2
1-2
24x
1-2
1-2
1-2
1-2
1-2
For example, “Athlon XP 2000+” is an 1666MHz CPU: 12.5 (Multiplier) X 133MHz (External frequency) = 1666MHz
FID jumpers setting:
The jumper caps are not provided by ASRock. Please understand that ASRock
does not guarantee and support the adjustment of multiplier. These jumpers
setting may not apply to all multiplier-locked or even some unlocked AMD
CPU. Frequencies other than the recommended CPU bus frequencies may
cause the instability of the system or damage the CPU.
1
1
1
1
1
FID0
FID1
FID2
FID3
FID4
1
1
1
1
1
FID0
FID1
FID2
FID3
FID4