Acer AR385 F1 Specifications - Page 5

Technical Specifications

Page 5 highlights

Acer AR385 F1 Specifications Technical Specifications Dimensions (with bezel) 438.4 mm (W) x 705 mm (D) x 88.1 mm (H) ( 17.3 x 27.8 x 3.5 inches) Form factor 2U rack optimized with cable arms included Weight (approximate) Maximum 39 kg (88.1 lbs) (All component slots and sockets fully installed) Minimum 28.5 kg (62.8 lbs) (One HDD, power supply, and processor installed) BTU rating Maximum 3276 BTU/hr System inlet temperature Operating Non-operating 10° - 35° C (50° - 95° F) at sea level with an altitude derating of 1° C per 305 m (1.8° F per 1000 ft.) above sea level to a maximum of 3050 m (10,000 ft.) no direct sustained sunlight. Maximum rate of change is 10°C/hr (18°F/hr). The upper limit depends the type and number of options installed. System performance may be reduced if operating with a fan fault or above 30°C (86°F). -40° - 70° C (-40° - 158° F) Maximum rate of change is 20°C/hr (36°F/hr). Relative humidity Operating (non-condensing) Non-operating 8 - 90 % relative humidity (Rh), 28° C (82.4° F) maximum wet bulb temperature, non-condensing 5 - 95 % relative humidity (Rh), 38.7° C (101.7° F) maximum wet bulb temperature, non-condensing Acoustic noise Listed are the declared A-weighted sound power levels (LWAd) and declared average bystander position A-weighted sound pressure levels (LpAm) when the product is operating in a 21° C ambient environment. Noise emissions were measured in accordance with ISO 7779. Idle LWAd: 6.4 BA/ LpAm: 45.8 dBA Operating LWAd: 7.2 BA / LpAm: 53.6 dBA Emissions classification (EMC) FCC rating Normative standards Class A EN55022, EN 61000-3-2, EN 61000-3-3, CISPR 22 Class A Power supply Rated Steady -state power Maximum Peak Power BTU rating 720 W 728 W 2456.64 BTU/hr at 100 - 240 VAC 5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

5
Acer AR385 F1 Specifications
Technical Specifications
Dimensions
(with bezel)
438.4 mm (W) x 705 mm (D) x 88.1 mm (H) ( 17.3 x 27.8 x 3.5 inches)
Form factor
2U rack optimized with cable arms included
Weight
(approximate)
Maximum
(All component slots and sockets
fully installed)
39 kg (88.1 lbs)
Minimum
(One HDD, power supply, and
processor installed)
28.5 kg (62.8 lbs)
BTU rating
Maximum
3276 BTU/hr
System inlet
temperature
Operating
10° - 35° C (50° - 95° F) at sea level with an
altitude derating of 1° C per 305 m (1.8° F per
1000 ft.) above sea level to a maximum of 3050 m
(10,000 ft.)
no direct sustained sunlight.
Maximum rate of change is 10°C/hr (18°F/hr).
The upper limit depends the type and number
of options installed. System performance may
be reduced if operating with a fan fault or
above 30°C (86°F).
Non-operating
-40° - 70° C (-40° - 158° F)
Maximum rate of
change is 20°C/hr (36°F/hr).
Relative humidity
(non-condensing)
Operating
8 - 90 % relative humidity (Rh), 28° C (82.4° F)
maximum wet bulb temperature, non-condensing
Non-operating
5 - 95 % relative humidity (Rh), 38.7° C (101.7° F)
maximum wet bulb temperature, non-condensing
Acoustic noise
Listed are the declared A-weighted sound power levels (LWAd) and declared
average bystander position A-weighted sound pressure levels (LpAm) when the
product is operating in a 21° C
ambient environment. Noise emissions were
measured in accordance with ISO 7779.
Idle
LWAd: 6.4 BA/ LpAm: 45.8 dBA
Operating
LWAd: 7.2 BA / LpAm: 53.6 dBA
Emissions
classification
(EMC)
FCC rating
Class A
Normative standards
EN55022, EN 61000-3-2, EN 61000-3-3, CISPR
22 Class A
Power supply
Rated Steady
state power
720 W
Maximum Peak Power
728 W
BTU rating
2456.64 BTU/hr at 100 - 240 VAC