Acer Aspire 7552G MSDS, UN38.3, CNAS of Battery pack for transportation - Page 5

UN Test Data, Model:3UR18650-2-T0638 - battery

Page 5 highlights

UN Test Data (Model:3UR18650-2-T0638) 1.Test Item: Altitude simulation (T1) 2.Test Purpose: This test simulates air transport under low-pressure conditions. 3.Test Procedure: Test cells and batteries shall be stored at a pressure of 11.6kPa or less for at least six hours at ambient temperature(20±5℃). SANYO Internal Procedure: As above. P.3/10 4.Test Requirements: No mass loss(less than 0.1%),no leakage,no venting,no disassembly,no rupture and no fire,and the voltage retention is not less than 90%. The requirement relating to voltage is not applicable to test batteries at fully discharged states. 5.Test Date: 22001100//11//77 6.Test Data Battery No. Mass(g) Mass loss Voltage(V) Voltage (%) Retention( Before test After test (=90%) Other event Result Judgement At first 1 327.73 cycle,in 2 328.58 fully charged 3 328.44 states 4 328.30 327.78 328.69 328.46 328.42 0.015 0.033 0.006 0.037 12.95 12.97 12.97 12.95 12.94 12.96 12.97 12.95 99.9 99.9 100.0 100.0 0 PASS 0 PASS 0 PASS 0 PASS At first 5 cycle,in 6 fully discharged 7 states 8 327.63 328.29 328.08 328.15 327.42 327.99 328.10 328.26 0.064 0.091 0.006 0.034 After 50 9 cycles ending in 10 fully 11 charged states 12 328.60 328.67 327.57 327.89 328.56 328.67 327.32 328.02 0.012 0.000 0.076 0.040 12.97 12.96 12.97 12.97 12.97 12.96 12.97 12.97 After 50 13 cycles ending in 14 fully 15 discharged states 16 327.33 327.78 328.51 328.31 327.37 328.02 328.65 328.36 0.012 0.073 0.043 0.015 Notes: L-Leakage, V-Venting, D-Disassembly, R-Rupture, F-Fire, 0-No leakage, no venting, no disassembly, no rupture & no fire 100.0 100.0 100.0 100.0 0 PASS PASS 0 PASS 0 PASS PASS 0 PASS 0 PASS 0 PASS 0 PASS 0 PASS 0 PASS 0 PASS 0 PASS

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

UN Test Data
(Model:3UR18650-2-T0638)
1.Test Item:
Altitude simulation (T1)
P.3/10
2.Test Purpose:
This test simulates air transport under low-pressure conditions.
3.Test Procedure:
Test cells and batteries shall be stored at a pressure of 11.6kPa or less
for at least
six hours at ambient
temperature(20±5
).
SANYO Internal Procedure:
As above.
4.Test Requirements:
No mass loss(less than 0.1%),no leakage,no venting,no disassembly,no rupture and no fire,and the voltage
retention is not
less than 90%.
The requirement relating to voltage is not applicable to test batteries at fully discharged states.
5.Test Date:
2010/1/7
6.Test Data
Before test
After test
Before test
After test
1
327.73
327.78
0.015
12.95
12.94
99.9
0
PASS
2
328.58
328.69
0.033
12.97
12.96
99.9
0
PASS
3
328.44
328.46
0.006
12.97
12.97
100.0
0
PASS
4
328.30
328.42
0.037
12.95
12.95
100.0
0
PASS
5
327.63
327.42
0.064
0
PASS
6
328.29
327.99
0.091
PASS
7
328.08
328.10
0.006
0
PASS
8
328.15
328.26
0.034
0
PASS
9
328.60
328.56
0.012
12.97
12.97
100.0
0
PASS
10
328.67
328.67
0.000
12.96
12.96
100.0
0
PASS
11
327.57
327.32
0.076
12.97
12.97
100.0
0
PASS
12
327.89
328.02
0.040
12.97
12.97
100.0
0
PASS
13
327.33
327.37
0.012
0
PASS
14
327.78
328.02
0.073
0
PASS
15
328.51
328.65
0.043
0
PASS
16
328.31
328.36
0.015
0
PASS
Notes: L-Leakage, V-Venting, D-Disassembly, R-Rupture, F-Fire,
0-No leakage, no venting, no disassembly, no rupture & no fire
Other
event
Result
Judgement
At first
cycle,in
fully
charged
states
PASS
At first
cycle,in
fully
discharged
states
After 50
cycles
ending in
fully
charged
states
After 50
cycles
ending in
fully
discharged
states
Battery No.
Mass(g)
Mass loss
(%)
(=<0.1%)
Voltage(V)
Voltage
Retention(
%)(=>90%)