Acer Veriton 3200 Veriton 3200 Service Guide - Page 24

Switching Power Supply 145W, Input Frequency, Frequency Variation Range, Input Voltage

Page 24 highlights

Switching Power Supply 145W 50Hz 60Hz Input Frequency 47Hz to 53Hz 57Hz to 63Hz Frequency Variation Range Input Voltage 100 - 120 VRMS 200 - 240 VRMS 90-132 VRMS 180-264 VRMS Variation Range Input Current 4A 3A 90 -132 VRMS 180 - 264 VRMS Measuring Range (This is for 145 power supply) NOTE: 1. This "4A" includes the outlet supply current: 2A. 2. Measure at line input 90VRMS and maximum load condition. Output Requirements +5V +12V -12V +3.3V -5V +5Vaux +-5% +-5% +-10% +-5% +-10% +-5% Regulation NOTE: +5V and 3.3V total power is 100W max. 15A 3A 0.3A 12A 0A 1A Current Rating Chapter 1 17

We apologize, but we cannot currently deliver this PDF manual by request of the manufacturer.

We apologize for any inconveniece.