Switching Power Supply 145W, Input Frequency, Frequency Variation Range, Input Voltage
View all Acer Veriton 3200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 24 highlights
Switching Power Supply 145W 50Hz 60Hz Input Frequency 47Hz to 53Hz 57Hz to 63Hz Frequency Variation Range Input Voltage 100 - 120 VRMS 200 - 240 VRMS 90-132 VRMS 180-264 VRMS Variation Range Input Current 4A 3A 90 -132 VRMS 180 - 264 VRMS Measuring Range (This is for 145 power supply) NOTE: 1. This "4A" includes the outlet supply current: 2A. 2. Measure at line input 90VRMS and maximum load condition. Output Requirements +5V +12V -12V +3.3V -5V +5Vaux +-5% +-5% +-10% +-5% +-10% +-5% Regulation NOTE: +5V and 3.3V total power is 100W max. 15A 3A 0.3A 12A 0A 1A Current Rating Chapter 1 17