Storage Manager on ROM Note: As reported means that the field displays the value returned by the controller firmware. Bus Each peripheral bus on a controller is assigned a number. Numbering starts with 0 for the first bus, 1 for the second bus, and so on. ID (SCSI only) SCSI RAID controllers are configured by default at ID 7. This value should not be changed unless required for special configurations. Type This is the type of bus (Ultra320, Ultra160, etc.). Width The width of the parallel bus (8-bit or 16-bit). Transfer Rate The controller automatically negotiates with each device at powerup or reset to set the maximum transfer rate. This parameter limits the transfer rate to the value selected. This setting should not be changed except when you are troubleshooting bus errors. Note: On buses, if setting this parameter to 5 MHz eliminates bus data errors, this is usually an indication that the bus is too long or that the bus is not terminated correctly. Termination This option controls the termination for the controller and bus. The default value (On) should not be changed unless both internal and external cables are attached to the controller. Refer to the Configuring Termination section in the Adaptec SCSI RAID Installation Guide for information on setting this parameter. 2-15