Adaptec 29320LPE User Guide - Page 47
Environmental Specifications, DC Power Requirements, Current Requirements
UPC - 760884154762
View all Adaptec 29320LPE manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 47 highlights
Appendix B: Technical Specifications ● 47 Environmental Specifications Operating temperature Relative humidity Recommended Op-Humidity Altitude 0 °C to 55 ° C 10% to 90% (non-condensing) 40% to 60%@ 22 °C 3,000m operating 4,500m non-operating Note: Forced airflow is recommended, but not required. DC Power Requirements Ripple and noise DC Voltage 50 mV peak-to-peak (max) 3.3 V ± 10%, 12 V ± 10% Current Requirements Adaptec Model Adaptec SCSI 29320LPE Maximum Current (A) 1.0 A @ 3.3 VDC; .20 A @ 12.0 VDC
Appendix B: Technical Specifications
●
47
Environmental Specifications
Note:
Forced airflow is recommended, but not required.
DC Power Requirements
Current Requirements
Operating temperature
0 °C to 55 °
C
Relative humidity
10% to 90%
(
non-condensing)
Recommended Op-Humidity
40% to 60%@ 22 °C
Altitude
3,000m operating
4,500m non-operating
Ripple and noise
50 mV peak-to-peak (max)
DC Voltage
3.3 V ± 10%, 12 V ± 10%
Adaptec Model
Maximum Current (A)
Adaptec SCSI 29320LPE
1.0 A @ 3.3 VDC; .20 A @ 12.0 VDC