Asus F1A55 User Manual - Page 63

CPU Voltage, 3.3V Voltage, 5V Voltage, 12V Voltage, Anti Surge Support [Enabled]

Page 63 highlights

The following four items appear only when you set Chassis Fan Profile to [Manual]. Chassis Upper Temperature [70ºC] Use the and keys to adjust the upper limit of the CPU temperature. The values range from 20ºC to 90ºC. Chassis Fan Max. Duty Cycle(%) [100%] Use the and keys to adjust the maximum chassis fan duty cycle. The values range from 40% to 100%. When the chassis temperature reaches the upper limit, the chassis fan will operate at the maximum duty cycle. Chassis Lower Temperature [20ºC] Displays the lower limit of the chassis temperature. CPU Fan Min. Duty Cycle(%) [40%] Use the and keys to adjust the minimum chassis fan duty cycle. The values range from 40% to 100%. When the chassis temperature is under 40ºC, the chassis fan will operate at the minimum duty cycle. 2.6.5 CPU Voltage, 3.3V Voltage, 5V Voltage, 12V Voltage The onboard hardware monitor automatically detects the voltage output through the onboard voltage regulators. Select Ignore if you do not want to detect this item. 2.6.6 Anti Surge Support [Enabled] This item allows you to enable or disable the Anti Surge function. Configuration options: [Disabled] [Enabled] Chapter 2: BIOS information 2-23

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70

Chapter 2: BIOS information
2-23
The following four items appear only when you set
Chassis Fan Profile
to [Manual].
Chassis Upper Temperature [70�C]
Use the <+> and <-> keys to adjust the upper limit of the CPU temperature. The values range
from 20ºC to 90ºC.
Chassis Fan Max. Duty Cycle(%) [100%]
Use the <+> and <-> keys to adjust the maximum chassis fan duty cycle. The values range
from 40% to 100%. When the chassis temperature reaches the upper limit, the chassis fan will
operate at the maximum duty cycle.
Chassis Lower Temperature [20�C]
Displays the lower limit of the chassis temperature.
CPU Fan Min. Duty Cycle(%) [40%]
Use the <+> and <-> keys to adjust the minimum chassis fan duty cycle. The values range from
40% to 100%. When the chassis temperature is under 40ºC, the chassis fan will operate at the
minimum duty cycle.
2.6.5
CPU Voltage, 3.3V Voltage, 5V Voltage, 12V Voltage
The onboard hardware monitor automatically detects the voltage output through the onboard
voltage regulators. Select
Ignore
if you do not want to detect this item.
2.6.6
Anti Surge Support [Enabled]
This item allows you to enable or disable the Anti Surge function.
Configuration options: [Disabled] [Enabled]