Water Pump+ Point4 Duty Cycle

Page 93 highlights

Water Pump+ Point4 Duty Cycle (%) When the temperature source is lower than the temperature of P4, the duty cycle will be determined according to the P3-P4 and the temperature source. When the temperature source is higher than the temperature of P4, the fan will operate at the duty cycle of P4. Use the or keys to adjust the fan/pump duty cycle. Water Pump+ Point3 Temperature When the temperature source is lower than the temperature of P3, the duty cycle will be determined according to the P2-P3 and the temperature source. When the temperature source is higher than the temperature of P3, the fan will operate at the duty cycle of P3-P4. Use the or keys to adjust the temperature. Water Pump+ Point3 Duty Cycle (%) When the temperature source is lower than the temperature of P3, the duty cycle will be determined according to the P2-P3 and the temperature source. When the temperature source is higher than the temperature of P3, the fan will operate at the duty cycle of P3-P4. Use the or keys to adjust the fan/pump duty cycle. Water Pump+ Point2 Temperature When the temperature source is lower than the temperature of P2, the duty cycle will be determined according to the P1-P2 and the temperature source. When the temperature source is higher than the temperature of P2, the fan will operate at the duty cycle of P2-P3. Use the or keys to adjust the temperature. Water Pump+ Point2 Duty Cycle (%) When the temperature source is lower than the temperature of P2, the duty cycle will be determined according to the P1-P2 and the temperature source. When the temperature source is higher than the temperature of P2, the fan will operate at the duty cycle of P2-P3. Use the or keys to adjust the fan/pump duty cycle. Water Pump+ Point1 Temperature When the temperature source is lower than the temperature of P1, the fan will operate at the duty cycle of P1. When the temperature source is higher than the temperature of P1, the duty cycle will be determined according to P1-P2 and the temperature source. Use the or keys to adjust the temperature. Water Pump+ Point1 Duty Cycle (%) When the temperature source is lower than the temperature of P1, the fan will operate at the duty cycle of P1. When the temperature source is higher than the temperature of P1, the duty cycle will be determined according to P1-P2 and the temperature source. Use the or keys to adjust the fan/pump duty cycle. AIO Pump Q-Fan Control Allows you to set the AIO Pump operating mode. [Auto Detect] Detects the type of installed fan/pump and automatically switches the control modes. [DC Mode] [PWM Mode] Enables the Q-Fan Control feature in DC mode for 3-pin fan/pump. Enables the Q-Fan Control feature in PWM mode for 4-pin fan/ pump. ROG Z790 Series (Intel® 14th) BIOS Manual 93

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110

ROG Z790 Series (Intel
®
14
th
) BIOS Manual
93
Water Pump+ Point4 Duty Cycle (%)
When the temperature source is lower than the temperature of P4, the duty cycle
will be determined according to the P3-P4 and the temperature source. When the
temperature source is higher than the temperature of P4, the fan will operate at the
duty cycle of P4. Use the <+> or <-> keys to adjust the fan/pump duty cycle.
Water Pump+ Point3 Temperature
When the temperature source is lower than the temperature of P3, the duty cycle
will be determined according to the P2-P3 and the temperature source. When the
temperature source is higher than the temperature of P3, the fan will operate at the
duty cycle of P3-P4. Use the <+> or <-> keys to adjust the temperature.
Water Pump+ Point3 Duty Cycle (%)
When the temperature source is lower than the temperature of P3, the duty cycle
will be determined according to the P2-P3 and the temperature source. When the
temperature source is higher than the temperature of P3, the fan will operate at the
duty cycle of P3-P4. Use the <+> or <-> keys to adjust the fan/pump duty cycle.
Water Pump+ Point2 Temperature
When the temperature source is lower than the temperature of P2, the duty cycle
will be determined according to the P1-P2 and the temperature source. When the
temperature source is higher than the temperature of P2, the fan will operate at the
duty cycle of P2-P3. Use the <+> or <-> keys to adjust the temperature.
Water Pump+ Point2 Duty Cycle (%)
When the temperature source is lower than the temperature of P2, the duty cycle
will be determined according to the P1-P2 and the temperature source. When the
temperature source is higher than the temperature of P2, the fan will operate at the
duty cycle of P2-P3. Use the <+> or <-> keys to adjust the fan/pump duty cycle.
Water Pump+ Point1 Temperature
When the temperature source is lower than the temperature of P1, the fan will operate
at the duty cycle of P1. When the temperature source is higher than the temperature
of P1, the duty cycle will be determined according to P1-P2 and the temperature
source. Use the <+> or <-> keys to adjust the temperature.
Water Pump+ Point1 Duty Cycle (%)
When the temperature source is lower than the temperature of P1, the fan will operate
at the duty cycle of P1. When the temperature source is higher than the temperature
of P1, the duty cycle will be determined according to P1-P2 and the temperature
source. Use the <+> or <-> keys to adjust the fan/pump duty cycle.
AIO Pump Q-Fan Control
Allows you to set the AIO Pump operating mode.
[Auto Detect]
Detects the type of installed fan/pump and automatically switches
the control modes.
[DC Mode]
Enables the Q-Fan Control feature in DC mode for 3-pin fan/pump.
[PWM Mode]
Enables the Q-Fan Control feature in PWM mode for 4-pin fan/
pump.