Asus ROG STRIX B250F GAMING STRIX B250F GAMING BIOS ManualEnglish - Page 27

Chassis Fan 1/2 Q-Fan Source [CPU], Chassis Fan 1/2 Speed Low Limit [200 RPM], Chassis Fan 1/2

Page 27 highlights

The following items appear only when you set the Chassis Fan 1/2 Q-Fan Control to [Auto], [PWM Mode], or [DC Mode]. Chassis Fan 1/2 Q-Fan Source [CPU] This item controls the assigned fan according to the selected temperature source. Configuration options: [CPU] [Motherboard] Chassis Fan 1/2 Speed Low Limit [200 RPM] This item allows you to disable or set the chassis fan warning speed. Configuration options: [Ignore] [200RPM] [300 RPM] [400 RPM] [500 RPM] [600 RPM] Chassis Fan 1/2 Profile [Standard] This item allows you to set the appropriate performance level of the chassis fan. [Standard] Sets to [Standard] to make the chassis fan automatically adjust depending on the chassis temperature. [Silent] Sets to [Silent] to minimize the fan speed for quiet chassis fan operation. [Turbo] Sets to [Turbo] to achieve maximum chassis fan speed. [Manual] Sets to [Manual] to assign detailed fan speed control parameters. The following four items appear only when you set Chassis Fan 1/2 Profile to [Manual]. Chassis Fan 1/2 Upper Temperature [70] Use the or keys to adjust the upper limit of the CPU temperature. The values range from 0°C to 75°C. Chassis Fan 1/2 Max. Duty Cycle(%) [100] Use the or keys to adjust the maximum chassis fan duty cycle. The values range from 60% to 100%. When the chassis temperature reaches the upper limit, the chassis fan will operate at the maximum duty cycle. Chassis Fan 1/2 Middle Temperature [45] Use the or keys to set the value for Chassis Fan Middle Temperature. Chassis Fan 1/2 Middle Duty Cycle(%) [60] Use the or keys to adjust the chassis fan middle duty cycle. The values range from 60% to 100%. Chassis Fan 1/2 Lower Temperature [40] Use the or keys to adjust the chassis fans' lower temperature. The values range from 0°C to 75°C. Chassis Fan 1/2 Min. Duty Cycle(%) [60] Use the or keys to adjust the minimum chassis fan duty cycle. The values range from 60% to 100%. When the CPU temperature is under the lower limit, the chassis fan operates at the minimum duty cycle. ASUS STRIX B250F GAMING 27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

ASUS STRIX B250F GAMING
27
The following items appear only when you set the Chassis Fan 1/2 Q-Fan Control to
[Auto],
[PWM Mode],
or
[DC Mode]
.
Chassis Fan 1/2 Q-Fan Source [CPU]
This item controls the assigned fan according to the selected temperature source.
Configuration options: [CPU] [Motherboard]
Chassis Fan 1/2 Speed Low Limit [200 RPM]
This item allows you to disable or set the chassis fan warning speed. Configuration options:
[Ignore] [200RPM] [300 RPM] [400 RPM] [500 RPM] [600 RPM]
Chassis Fan 1/2 Profile [Standard]
This item allows you to set the appropriate performance level of the chassis fan.
[Standard]
Sets to [Standard] to make the chassis fan automatically adjust depending
on the chassis temperature.
[Silent]
Sets to [Silent] to minimize the fan speed for quiet chassis fan operation.
[Turbo]
Sets to [Turbo] to achieve maximum chassis fan speed.
[Manual]
Sets to [Manual] to assign detailed fan speed control parameters.
The following four items appear only when you set
Chassis Fan 1/2 Profile
to [Manual].
Chassis Fan 1/2 Upper Temperature [70]
Use the <+> or <-> keys to adjust the upper limit of the CPU temperature. The values
range from 0
°
C to 75
°
C.
Chassis Fan 1/2 Max. Duty Cycle(%) [100]
Use the <+> or <-> keys to adjust the maximum chassis fan duty cycle. The values
range from 60% to 100%. When the chassis temperature reaches the upper limit, the
chassis fan will operate at the maximum duty cycle.
Chassis Fan 1/2 Middle Temperature [45]
Use the <+> or <-> keys to set the value for Chassis Fan Middle Temperature.
Chassis Fan 1/2 Middle Duty Cycle(%) [60]
Use the <+> or <-> keys to adjust the chassis fan middle duty cycle. The values range
from 60% to 100%.
Chassis Fan 1/2 Lower Temperature [40]
Use the <+> or <-> keys to adjust the chassis fans’ lower temperature. The values
range from 0
°
C to 75
°
C.
Chassis Fan 1/2 Min. Duty Cycle(%) [60]
Use the <+> or <-> keys to adjust the minimum chassis fan duty cycle. The values
range from 60% to 100%. When the CPU temperature is under the lower limit, the
chassis fan operates at the minimum duty cycle.