Axis Communications 215 PTZ 215 PTZ - Installation Guide - Page 16
LED indicators, Resetting to the Factory Default Settings, Connection diagram - firmware
View all Axis Communications 215 PTZ manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 16 highlights
Page 16 Connection diagram AXIS 215 PTZ 12V max. 100mA AXIS 215 PTZ Installation Guide 1o e.g. pushbutton 2o z 3o 4 o LED indicators LED Network Status Power Color Green Amber Unlit Green Amber Red Green Amber Indication Steady for connection to a 100 Mbit/s network. Flashes for network activity. Steady for connection to 10 Mbit/s network. Flashes for network activity. No network connection. Steady green for normal operation. Steady during startup, during reset to factory default or when restoring settings. Slow flash for failed upgrade. Normal operation. Flashes green/amber during firmware upgrade. Resetting to the Factory Default Settings This will reset all parameters, including the IP address, to the factory default settings: 1. Disconnect power from the camera. 2. Press and hold the Control button and reconnect power. 3. Keep the Control button pressed until the Status indicator displays amber (this may take up to 15 seconds), then release the button. 4. When the Status indicator displays green (which can take up to 1 minute) the process is complete and the camera has been reset. 5. Re-assign the IP address, using one of the methods described in this document. It is also possible to reset parameters to the original factory default settings via the web interface. For more information, please see the online help or the user's manual.