Beko DTGC8011 Owners Manual - Page 17
For the condenser
View all Beko DTGC8011 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 17 highlights
If you forget to drain the water tank, the machine will stop during the subsequent drying cycles when the water tank is full and the Water Tank warning symbol will flash. If this is the case, drain the water tank and press Start / Pause button to resume the drying cycle. To drain the water tank: 1. Remove the water tank in the drawer or container carefully. • Unlock the 2 condenser locks after opening the kick plate • Pull out the condenser. 2. Drain the water in the tank. Clean the condenser by applying pressurized water with a shower armature and wait until the water drains. • If there is lint accumulation in the funnel of the water tank, clean it under running water. • Place the water tank into its seat. C NOTE • If the direct water draining is used as an option, there is no need to empty the water tank. 6.4 For the condenser; C NOTE • Clean the condenser after every 30 drying cycles or once a month. To clean the condenser: If a drying process has been carried out, open the door of the machine and wait until it cools down. Place the condenser in its housing. Fasten the 2 locks and make sure that they are seated securely. Close the kick plate cover. Dryer / User Manual 17