Beko HIAW75224S User Manual - Page 15
screwdriver
View all Beko HIAW75224S manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
2 4 1 Flame failure device (model dependant) 2 Spark plug 3 Injector 4 Burner 5. For the last control, bring the burner both to high- flame and reduced positions and check whether the flame is on or off. Depending on the type of gas tap used in your appliance the adjustment screw position may vary. ()kJ 400 7 , 1 *0 p0 Unless there is an abnormal condition, do not .ttempt to remove the gas burner taps. You must call an Authorised service agent or technician with licence if it is necessary to change the taps. 1 Flow rate adjustment screw 400 OO Reduced gas flow rate setting for hob taps 1. Ignite the burner that is to be adjusted and turn the knob to the reduced position. 2. Remove the knob from the gas tap. 3. Use an appropriately sized screwdriver to adjust the flow rate adjustment screw. For LPG (Butane - Propane) turn the screw clockwise. For the natural gas, you should turn the screw counter-clockwiseonce. » The normal length of a straight flame in the reduced 1 Flow rate adjustment screw position should be 6-7 mm. 4. If the flame is higher than the desired position, turn the screw clockwise. If it is smaller turn anticlockwise. If the gas type of the unit is changed, then the rating plate that shows the gas type of the unit must also be changed. 1 5/EN