Beko HIZG64120 User Manual - Page 13
authorised
View all Beko HIZG64120 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 13 highlights
NOTICE /) New injectors have their position marked on their packing or table can be referred Important Unless there is an abnormal condition, do not attempt to remove the gas burner taps. You must call the authorised service if it is necessary to change the taps. 4. If the flame is higher than the desired position, turn the screw clockwise. If it is smaller turn to the opposite. 5. For the last control, bring the burner both to high-flame and reduced positions and check whether the flame is on or off. Depending on the type of gas tap used in your appliance the adjustment screw position may vary. See below diagrams. 2 3 1 Sparking plug 2 Injector 3 Burner Reduced gas flow rate setting for hob taps 1 Flow rate adjustment screw 00 00 1. Ignite the burner that should be adjusted and turn the knob to the reduced position. 2. Take out the knob off. 3. With a screwdriwer, make the tap reduced flow adjustment from the injector that is on the gas tap. 1 Flow rate adjustment screw For LPG (Butane - Propane) turn the screw clockwise. For the natural gas, you should turn the screw counter-clockwise once. The normal length of a straight flame in the reduced position should be 6-7 mm. NOTICE If the gas type of the unit is changed, then the rating plate that shows the gas type of the unit must also be changed. 131 EN