Beko HQAW75225S User Manual - Page 12
Installation, connection
View all Beko HQAW75225S manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 12 highlights
Total gas consumption (kW) 0-2 2-3 3-4 4-6 6-8 8-10 10-11.5 11.5-13 13-15.5 15.5-17 17-19 19-24 min. Ventilation opening (cm2) 100 120 175 300 400 500 600 700 800 900 1000 1250 Installation and connection CAUTION • This appliance is designed for cooking purposes only, and `s€ intended for indoor domestic household and static home use only. • This appliance should not be used for any other purpose or in any other application, such as for non-domestic use or in a commercial environment. • In addition this appliance is not suitable for use on any type of boat (offshore, inland waterway, canal boat or houseboat), caravans or motor homes. Installation in static caravans and mobile homes is permitted. • Incorrect installation environments will void the guarantee. • This appliance should not be used for room heating purposes. • The manufacturer shall not be liable for any damage caused by improper use or handling. • The product must be installed in accordance with all local gas and electrical regulations. Electrical connection Connect the product to a grounded outlet/line protected by a fuse of suitable capacity as stated in the "Technical specifications" table. Have the grounding installation made by a qualified electrician while using the product with or without a transformer. Our company shall not be liable for any damages that will arise due to using the product without a grounding installation in accordance with the local regulations. ii DANGER: / /•T\\ The product must be connected to the mains supply only by an authorised and qualified person. The product's warranty period starts only after correct installation. Manufacturer shall not be held responsible for damages arising from procedures carried out by unauthorised persons. A, DANGER: * I The power cable must not be clamped, bent or trapped or come into contact with hot parts of the product. A damaged power cable must be replaced by a qualified electrician. Otherwise, there is risk of electric shock, short circuit or fire! • Connection must comply with national regulations. • The mains supply data must correspond to the data specified on the type label of the product. Type label is at the rear housing of the product. A,I• Power cable of your product must comply with the values in "Technical specifications" table. DANGER: Before starting any work on the electrical • installation, disconnect the product from the mains supply. There is the risk of electric shock! Connecting the power cable 1. If a power cable is not supplied together with your product, a power cable that you would select from the table in accordance with the electrical installation at your home must be connected to your product by following the instructions in cable diagram. This product must only be connected by a qualified electrician such as a technician from the local electricity company or NICEIC registered contractor to a suitable double-pole control unit with a minimum contact clearance of 3 mm in all poles. This control unit must be installed accordance with the IEE regulation. Failure to obey this instruction may cause operational problems and invalidate the product warranty. Additional protection by a residual current circuit breaker is recommended. 12/EN 2. Open the terminal block cover with a screwdriver 3. Insert the power cable through the cable clamp below the terminal and secure it to the main body