Belkin F5D5141-24 User Manual - Page 13
Troubleshooting
UPC - 722868510865
View all Belkin F5D5141-24 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 13 highlights
Troubleshooting Diagnosing Switch Indicators Symptom Power LED does not light after power on. Probable Causes AC power cord may be defective. Possible Solutions • Check for loose connections. • Check the power outlet by using it for another device. • Replace the AC power cord. Symptom Port (Link/Act) LED does not light after connection is made. Probable Causes Switch port, network card, or cable may be defective. Possible Solutions • Check that the Switch and attached device are both powered on. • Be sure the network cable is connected to both devices. • Verify that Category 5 or better cable is used for 10/100Mbps connections; Category 5, 5e, or 6 cable for 1000Mbps connections; and that the length of any cable does not exceed 328 feet (100m). • Check the network card and cable connections for defects. • Replace the defective card or cable if necessary. 10