Belkin F6C110-RKM-2U Belkin OmniGuard Rackmount UPS Software Manual - Page 49
Edit configuration files- DSO Installation - property management
View all Belkin F6C110-RKM-2U manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 49 highlights
OmniGuardTM UPS Power Management Software Edit configuration files- DSO Installation * Edit /usr/local/apache/conf/httpd.conf Add line: LoadModule jserv_module libexec/mod_jserv.so Add line: AddModule mod_jserv.c Add line: include /usr/local/apache/conf/jserv/jserv.conf * Edit /usr/local/apache/conf/jserv/jserv.conf Addline:ApJServProperties /usr/local/apache/conf/jserv/jserv.properties Add line: ApJServLogFile /usr/local/apache/conf/jserv/mod_jserv.log Add line: ApJServMount /servlets/servlets ( Comment out other entries) * Edit /usr/local/apache/conf/jserv/jserv.properties Add line: zones=sevlets ( Comment out other entries) Addline:servlets.properties=/usr/local/apache/conf/jserv/servlets.pr operties ( Comment out other entries) Add line: /usr/local/apache/conf/jserv/servlets.properties Add line: respositories=/usr/local/apache/servlets Execute the line. cp /usr/local/apache/conf/jserv/zone.properties /usr/local/apache/conf/jserv/servlets.properties Installation on linux with script: 49