Belkin F6C1500-TW-RK User Manual - Page 2

D Uninstall for Windows 98/ Me/ NT4/ 2000 / 2003/ XP - warranty

Page 2 highlights

You may connect the UPS to your computer by choosing either the Serial or USB ports. Note: Choose one port only. Do not connect your computer through both ports. Software Installation (Installation Optional) A) To fully utilize the UPS and its software, your computer must be able to operate the following operating systems: Windows98/ ME/ NT4/ 2000 / 2003/ XP and have a USB port. B) Your UPS features the Bulldog Plus Shutdown Software. This allows you to protect and save your data should a power outage occur, as well as safely shutdown your computer in your absence. Please be sure to close out of all applications prior to installing the software. 1. To install the software, please place the CD into the CD drive of your computer. 2. Your computer should autorun the CD. If this does not occur, go to the Run feature on your Start icon (lower left corner) on your screen. Please enter the CD drive, it may be D: Upon entering the drive run setup.exe. to execute the software. Should you continue to have a problem, please refer to your computer's owner's manual for the correct drive. 3. The "Welcome to the Belkin Bulldog Plus Product Installation Browser" will appear. Please click Install and select the Windows version. 4. The Bulldog Plus Installation window will appear. Please choose the appropriate software to install. 5. Install Shield Wizard will appear onscreen, click Next. 6. Please read the License Agreement and click Yes. 7 On Setup Type, ALL (Standalone) is the default. Standalone is for UPS management for your computer only. Networking management is for administrators who need to manage several UPSes in a workstation environment. You should not install the networking files unless you are technically qualified to use these features. For more information on networking, please refer to the software user's manual. 8. On Choose Destination Folder, you have the option to choose the location of where you would like the Software located on your computer. We recommend using the default option as shown on screen. To use the default option, click Next. 9. On Select Program Folder, you have the option to choose the program folder for your Software. We recommend using the default option as shown on screen. To use the default option, click Next. 10. On the Select Language screen, please select your language choice. 11. The software will now be installed. Once completed, please click Finish. Note! Please refer to the help feature found on the Belkin On-line Screen. To access this screen, please click the Belkin shield found in the lower right corner on your task bar of your screen. Once the Belkin On-line screen appears, choose help. The Bulldog Online Help screen will appear. You may use the Contents, Index or Search tabs to assist you with your help issues and to get more information on the specific features and functions of the software. C) User Manual Installation You will need Adobe Acrobat Reader to review the User's Manuals. If you do not have the reader, please goto www.adobe.com to download a free version of the software. 1. From the "Welcome to the Belkin Bulldog Plus Product Installation Browser" window, locate and choose User Manual's. 2. The "Bulldog Plus User Manuals" window will appear. Please move your pointer to the manual you wish to open and click. 3. An Adobe PDF file will be opened. To save a copy to your hard drive, you will need to goto "File" on your menu bar and choose "Save a copy". 4. On the Save a Copy window, please choose a destination folder for the manual. D) Uninstall for Windows 98/ Me/ NT4/ 2000 / 2003/ XP There are two options to uninstall the Belkin Shutdown Software. Option 1 1. Click the Start icon in the lower left hand corner of your screen and goto the Programs folder. Scroll to the Belkin Bulldog Plus folder and choose setup. Install Wizard will appear. 2. Choose Remove and click Next. 3. The Program Files and Audio Files will be checked. If they are not, please check them. Click Next. The uninstall procedure will begin. 4. Click Finish when complete. Option 2 (Note: Windows2000/ 2003/ XP users choose the Control panel function from your Start icon and then goto to step 2.) 1. Click the Start icon in the lower left hand corner of your screen and goto the Settings icon. Goto and choose the Control Panel folder. The Control Panel window will appear. 2. Locate and click the Add/Remove Programs icon. The Add/Remove Programs window will appear. 3. Locate and choose the Belkin Bulldog Plus software. Click the Change/Remove button on the right. Install Wizard will appear. 4. Choose Remove and click Next. 5. The Program Files & Audio Files will be checked. If they are not, please check them. Click Next. The uninstall procedure will begin. 6. Click Finish when complete. TECHNICAL SPECIFICATIONS MODEL INPUT Capacity Voltage Range Frequency F6C1000- F6C1250- F6C1500- TW-RK TW-RK TW-RK 1000VA/ 1250VA/ 1500VA/ 615W 680W 830W 88-140Vac 60HZ ( ±3HZ ) Voltage Simulated sine wave, 120vac±10% OUTPUT Frequency (On battery) 60HZ ( ±1HZ ) BATTERY Back up time 50%~100% load 1.5~6 mins 1.5~6 mins 1.5~5 mins Typical Recharge Time ≦ 12hours recover 85% capacity ENVIRONMENT Ambient operation 0~85% humidity non-condensing, 0~40℃ CONFORMANCE Safety Surge UL / c-UL, FCC class B IEEE C62.41 Category A standard PHYSICAL Dimension (W X H X D) Net weight 3.46 x 14.96 x 13.13 inches (88 x 380 x 333.5 mm) 9.2kg/ 20.24lbs 10.7kg/ 23.54 lbs All specifications are subject to change without prior notice. STORAGE Storage Conditions Store the UPS covered and upright in a cool, dry location with its battery fully charged. Before storing, charge the UPS for at least four hours. Disconnect any cables connected to the computer interface port to avoid unnecessary drainage of the battery. Extended Storage During extended storage in environments where the ambient temperature is +5 oF to +86 oF, charge the UPS battery every six months. During extended storage in environments where the ambient temperature is +86 oF to +113 oF, charge the UPS battery every three months. Note: Away from sunlight Away from heat Away from BELKIN COMPONENTS USER LICENSE AGREEMENT Belkin Components (Belkin") thanks you for choosing one of our products. This User License Agreement (Agreement") contains the terms and conditions under which limited use of the product is licensed to you. PLEASE READ THIS NOTICE CAREFULLY. DO NOT USE THE SOFTWARE OR PRODUCT UNTIL YOU HAVE READ AND AGREED TO THIS AGREEMENT. IF YOU USE THE SOFTWARE AND PRODUCT, YOU ARE AGREEING TO THE TERMS AND CONDITIONS SET OUT IN THIS AGREEMENT. IF YOU DO NOT ACCEPT THESE TERMS AND CONDITIONS, YOU MUST RETURN THE UNOPENED PRODUCT WITH THE DISKS INSIDE TO THE PARTY FROM WHOM YOU RECEIVED IT. SCOPE OF USE: In this Agreement, software means all machine-readable software programs and associated files in this package. All modified versions of and upgrades or improvements to such programs and all copies of such programs and files. You, a single user opening this envelope (You or our), may use the software on a single central processing unit. You may not rent it, loan it out, or lease it, nor use it on a multi-user system. LICENSE: You have the non-exclusive right to use the software. You are not permitted to copy, modify or transfer the software or documentation. You may not compile, disassemble or otherwise reverse engineer, breakdown, analyze or modify the software. USE AND RESTRICTIONS: You are permitted to make backup copies of all the software disks for archival purposes only. You must reproduce the proprietary notice set forth on the disks and affix them to all backup copies. You are not permitted to use these programs in connection with a computer service, or to use the backup copies other than as a replacement for the original copy. TERM: This license is effective upon acceptance by opening this envelope or in any other way using the enclosed software, which will constitute your acceptance of, and agreement to, this Agreement, and is effective until terminated. The limited license in this Agreement will be automatically terminated if you fail to comply with any of the Terms and conditions in this Agreement. You agree that upon such termination you will immediately destroy all programs and documentation, including all copies made or obtained by you. SOFTWARE, PROGRAM, DOCUMENTATION, AND ANY RELATED INFORMATION, GOODS OR SERVICES ARE PROVIDED WITH NO WARRANTY OR REPRESENTATION OF ANY KIND WHAT SO EVER. BELKIN HEREBY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. The entire risk of the use, results and performance of the software, program and documentation is borne by you. Should any or all of the product, software, program, documentation, or related information, goods or services be defective, misused, unsuitable or cause or give rise to any harm or liability whatsoever, you, not Belkin or its associates, dealers or agents, assume the entire liability, cost of repair, correction or any payment or other remedy whatsoever. Furthermore, no warranty or guarantee is made regarding the use or results of the product, software, program, documentation, or any related information, goods or services in terms of correctness, accuracy, reliability, timeliness or otherwise. You use and rely on the program at your own risk. The following is the only and exclusive warranty and remedy of any kind: Belkin does warrant that the program disks are free from physical defects in materials and workmanship under normal use for a period of one (1) year from the date of purchase, as evidenced by a copy of the sales receipt. Return the defective disk or documentation with your receipt directly to Belkin for a replacement. DISCLAIMER: Belkin or its associates will in no event be liable (i) in any amount for lost profits or special, incidental, punitive or consequential damages, or (ii) for any claim or damage of any nature, or under any theory, whatsoever, in any amount in excess of the purchase price you paid for the product. The warranties and remedies here set forth are exclusive, and in lieu of all others oral or written, express or implied. Some jurisdictions do not allow exclusion or limitation of implied warranties or of liability for incidental damages, so the foregoing limitations or exclusion may not apply to you. This warranty gives you specific legal rights, which vary from jurisdiction to jurisdiction. HOWEVER, YOU WAIVE SUCH RIGHTS, EXCEPT AS EXPRESSLY PROVIDED UNDER THE TERMS AND CONDITIONS OF THIS AGREEMENT, TO THE MAXIMUM EXTENT ALLOWED BY LAW. The license is governed by the laws prevailing in the State of New York, without regard to its conflicts of laws principles. ACKNOWLEDGMENT: By opening the package on which this Agreement is printed, or through which it is visible, you acknowledge that you have read this Agreement, understand it, and agree that this agreement is the complete and exclusive statement of agreement between yourself and Belkin and supersedes any prior agreements, oral or written, and any other communications relating to the subject matter of this Agreement. SEVERABILITY: Any term or provision of this Agreement or any application thereof, which may be prohibited or unenforceable by law in a particular jurisdiction, shall be interpreted and enforced to the maximum extent allowed in such jurisdiction (which the parties acknowledge could mean severing the provision from this Agreement or, if allowed, enforcing it in a narrower form), without affecting the remainder of this Agreement, or any other application of such term or provision in such jurisdiction, or application of such term or provision in any jurisdiction. SAFETY INFORMATION CAUTION! Internal battery voltage is 12V DC. The unit is intended for installation in a controlled environment (temperature controlled, indoor area free of conductive contaminants). All batteries used are Sealed Lead Batteries. Batteries must be recycled. Recycling Information Your UPS contains a Non-spillable Sealed Lead Battery. On the battery, you will find the battery name. Please reference the chart below for recycling information. Battery Name Recycling Recycling Outside Inside the the USA USA BB Battery (800) 278-8599 N/A CSB Battery VISION Battery RITAR Battery (800) 738-7372 (973) 726-5323 (888) 841-5179 1 (817) 244-4415 N/A N/A PROBLEM UPS not on, LED not lit UPS always on battery mode Back up time too short The UPS continuously beeps Red LED lit TROUBLE SHOOTING POSSIBLE CAUSE SOLUTION On/ Off /Test button Press the On/Off not pushed or pushed /Test button for more less than 2 second than 2 seconds Battery voltage is too Recharge the UPS at low least eight hours UPS fault Contact service personnel Power cord loose Re-plug the power cord AC breaker is burned Replace or reset the out or tripped breaker Ac utility voltage is too high or too low, or Normal condition black out Battery not fully Recharge the UPS at charged least eight hours UPS is overload Remove some un-necessary loads Charger fault or other Replace battery. reason Contact belkin.com Overload Battery failure Remove the non-critical loads Replace battery. Contact belkin.com CONTACT US Belkin Components, Ltd Belkin Components, Ltd 501 West Walnut St. Unit 13 • Gatelodge Close • Compton, CA • 90220-5221 USA Round Spinney Tel: 310.898.1100 Northampton, NN3 8RX UK Fax: 310.898.1111 Tel: +44 (0) 1604678300 • Fax: +44 (0) 1604678330 Belkin Components B.V. Starparc Building Boeing Avenue 3331119 PH Schiphol-Rijk The Netherlands Tel: +31 (0) 20 654 73 00 Fax: +31 (0) 20 654 73 49 Belkin Australia Ltd 7 Bowen Cresent West Gosford, NSW 2250 Tel: +61 (02) 4325 4666 Fax: +61 (02) 4325 4277 Please visit www.Belkin.com for battery replacement information. © 2004 Belkin Components. All rights reserved. All trade names are registered trademarks of respective manufacturers listed. P/N: 50113xxxxx

  • 1
  • 2

You may connect the UPS to your computer by choosing
either the Serial or USB ports.
Note: Choose one port only.
Do not connect your computer through both ports.
Software Installation (Installation Optional)
A)
To fully utilize the UPS and its software, your computer
must be able to operate the following operating systems:
Windows98/ ME/ NT4/ 2000 / 2003/ XP and have a USB
port.
B)
Your UPS features the Bulldog Plus Shutdown Software.
This allows you
to protect and save your data should a
power outage occur, as well as safely shutdown your
computer in your absence. Please be sure to close out of
all applications prior to installing the software.
1.
To install the software, please place the CD into the CD
drive of your computer.
2.
Your computer should autorun the CD. If this does not
occur, go to the Run feature on your Start icon (lower left
corner) on your screen. Please enter the CD drive, it may
be D: Upon entering the drive run setup.exe. to execute
the software. Should you continue to have a problem,
please refer to your computer’s owner’s manual for the
correct drive.
3.
The “Welcome to the Belkin Bulldog Plus Product
Installation Browser” will appear. Please click Install and
select the Windows version.
4.
The Bulldog Plus Installation window will appear. Please
choose the appropriate software to install.
5.
Install Shield Wizard will appear onscreen, click Next.
6.
Please read the License Agreement and click Yes.
7
On Setup Type, ALL (Standalone) is the default.
Standalone is for UPS management for your computer
only. Networking management is for administrators who
need to manage several UPSes in a workstation
environment. You should not install the networking files
unless you are technically qualified to use these features.
For more information on networking, please refer to the
software user’s manual.
8.
On Choose Destination Folder, you have the option to
choose the location of where you would like the Software
located on your computer.
We recommend using the
default option as shown on screen. To use the default
option, click Next.
9.
On Select Program Folder, you have the option to
choose the program folder for your Software. We
recommend using the default option as shown on screen.
To use the default option, click Next.
10. On the Select Language screen, please select your
language choice.
11. The software will now be installed. Once completed,
please click Finish.
Note!
Please refer to the help feature found on the Belkin On-line
Screen. To access this screen, please click the Belkin shield
found in the lower right corner on your task bar of your
screen.
Once the Belkin On-line screen appears, choose help. The
Bulldog Online Help screen will appear. You may use the
Contents, Index or Search tabs to assist you with your help
issues and to get more information on the specific features
and functions of the software.
C) User Manual Installation
You will need Adobe Acrobat Reader to review the User’s
Manuals. If you do not have the reader, please goto
www.adobe.com to download a free version of the software.
1.
From the “Welcome to the Belkin Bulldog Plus Product
Installation Browser” window, locate and choose User
Manual’s.
2.
The “Bulldog Plus User Manuals” window will appear.
Please move your pointer to the manual you wish to
open and click.
3.
An Adobe PDF file will be opened. To save a copy to
your hard drive, you will need to goto “File” on your menu
bar and choose “Save a copy”.
4.
On the Save a Copy window, please choose a
destination folder for the manual.
D) Uninstall for Windows 98/ Me/ NT4/ 2000 / 2003/ XP
There are two options to uninstall the Belkin Shutdown
Software.
Option 1
1.
Click the Start icon in the lower left hand corner of your
screen and goto the Programs folder. Scroll to the Belkin
Bulldog Plus folder and choose setup.
Install Wizard
will appear.
2.
Choose Remove and click Next.
3.
The Program Files and Audio Files will be checked. If
they are not, please check them. Click Next. The
uninstall procedure will begin.
4.
Click Finish when complete.
Option 2
(Note: Windows2000/ 2003/ XP users choose the
Control panel function from your Start icon and then
goto to step 2.)
1.
Click the Start icon in the lower left hand corner of your
screen and goto the Settings icon. Goto and choose
the Control Panel folder. The Control Panel window will
appear.
2.
Locate and click the Add/Remove Programs icon. The
Add/Remove Programs window will appear.
3.
Locate and choose the Belkin Bulldog Plus software.
Click the Change/Remove button on the right. Install
Wizard will appear.
4.
Choose Remove and click Next.
5.
The Program Files & Audio Files will be checked. If
they are not, please check them. Click Next. The
uninstall procedure will begin.
6.
Click Finish when complete.
TECHNICAL SPECIFICATIONS
MODEL
F6C1000-
TW-RK
F6C1250-
TW-RK
F6C1500-
TW-RK
Capacity
1000VA/
615W
1250VA/
680W
1500VA/
830W
Voltage Range
88-140Vac
INPUT
Frequency
60HZ (
±
3HZ )
Voltage
Simulated sine wave, 120vac
±
10%
OUTPUT
Frequency
(On battery)
60HZ (
±
1HZ )
Back up time
50%~100% load
1.5~6 mins 1.5~6 mins
1.5~5 mins
BATTERY
Typical Recharge
Time
12hours recover 85% capacity
ENVIRONMENT
Ambient operation
0~85% humidity non-condensing,
0~40
Safety
UL / c-UL, FCC class B
CONFORMANCE
Surge
IEEE C62.41 Category A standard
Dimension
(W X H X D)
3.46 x 14.96 x 13.13 inches
(88 x 380 x 333.5 mm)
PHYSICAL
Net weight
9.2kg/
20.24lbs
10.7kg/
23.54 lbs
All specifications are subject to change without prior notice.
STORAGE
Storage Conditions
Store the UPS covered and upright in a cool, dry location with its
battery fully charged. Before storing, charge the UPS for at least
four hours. Disconnect any cables connected to the computer
interface port to avoid unnecessary drainage of the battery.
Extended Storage
During extended storage in environments where the ambient
temperature is +5
o
F to +86
o
F, charge the UPS battery every six
months. During extended storage in environments where the
ambient temperature is +86
o
F to +113
o
F, charge the UPS battery
every three months.
Note:
BELKIN COMPONENTS USER LICENSE AGREEMENT
Belkin Components (Belkin”) thanks you for choosing one of our
products. This User License Agreement (Agreement”) contains the
terms and conditions under which limited use of the product is
licensed to you.
PLEASE READ THIS NOTICE CAREFULLY. DO NOT USE THE
SOFTWARE OR PRODUCT UNTIL YOU HAVE READ AND
AGREED TO THIS AGREEMENT. IF YOU USE THE SOFTWARE
AND PRODUCT, YOU ARE AGREEING TO THE TERMS AND
CONDITIONS SET OUT IN
THIS AGREEMENT. IF YOU DO NOT ACCEPT THESE TERMS
AND CONDITIONS, YOU MUST RETURN THE UNOPENED
PRODUCT WITH THE DISKS INSIDE TO THE PARTY FROM
WHOM YOU RECEIVED IT.
SCOPE OF USE:
In this Agreement, software means all
machine-readable software programs and associated files in this
package. All modified versions of and upgrades or improvements to
such programs and all copies of such programs and files. You, a
single user opening this envelope (You or our), may use the
software on a single central processing unit. You may not rent it,
loan it out, or lease it, nor use it on a multi-user system.
LICENSE:
You have the non-exclusive right to use the software.
You are not permitted to copy, modify or transfer the software or
documentation. You may not compile, disassemble or otherwise
reverse engineer, breakdown, analyze or modify the software.
USE AND RESTRICTIONS:
You are permitted to make backup
copies of all the software disks for archival purposes only. You must
reproduce the proprietary notice set forth on the disks and affix
them to all backup copies. You are not permitted to use these
programs in connection with a computer service, or to use the
backup copies other than as a replacement for the original copy.
TERM:
This license is effective upon acceptance by opening this
envelope or in any other way using the enclosed software, which will
constitute your acceptance of, and agreement to, this Agreement,
and is effective until terminated. The limited license in this
Agreement will be automatically terminated if you fail to comply with
any of the Terms and conditions in this Agreement. You agree that
upon such termination you will immediately destroy all programs and
documentation, including all copies made or obtained by you.
SOFTWARE, PROGRAM, DOCUMENTATION, AND ANY
RELATED INFORMATION, GOODS OR SERVICES ARE
PROVIDED WITH NO WARRANTY OR REPRESENTATION OF
ANY KIND WHAT SO EVER. BELKIN HEREBY DISCLAIMS ALL
OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE.
The entire risk of the use, results and performance of the software,
program and documentation is borne by you. Should any or all of the
product, software, program, documentation, or related information,
goods or services be defective, misused, unsuitable or cause or give
rise to any harm or liability whatsoever, you, not Belkin or its
associates, dealers or agents, assume the entire liability, cost of
repair, correction or any payment or other remedy whatsoever.
Furthermore, no warranty or guarantee is made regarding the use or
results of the product, software, program, documentation, or any
related information, goods or services in terms of correctness,
accuracy, reliability, timeliness or otherwise.
You use and rely on
the program at your own risk. The following is the only and exclusive
warranty and remedy of any kind: Belkin does warrant that the
program disks are free from physical defects in materials and
workmanship under normal use for a period of one (1) year
from the date of purchase, as evidenced by a copy of the sales
receipt.
Return the defective disk or documentation with your
receipt directly to Belkin for a replacement.
DISCLAIMER:
Belkin or its associates will in no event be
liable (i) in any amount for lost profits or special, incidental,
punitive or consequential damages, or (ii) for any claim or
damage of any nature, or under any theory, whatsoever, in
any amount in excess of the purchase price you paid for the
product. The warranties and remedies here set forth are
exclusive, and in lieu of all others oral or written, express or
implied. Some jurisdictions do not allow exclusion or limitation
of implied warranties or of liability for incidental damages, so
the foregoing limitations or exclusion may not apply to you.
This warranty gives you specific legal rights, which vary from
jurisdiction to jurisdiction.
HOWEVER, YOU WAIVE SUCH RIGHTS, EXCEPT AS
EXPRESSLY PROVIDED UNDER THE TERMS AND
CONDITIONS OF THIS AGREEMENT, TO THE MAXIMUM
EXTENT ALLOWED BY LAW.
The license is governed by the laws prevailing in the State of
New York, without regard to its conflicts of laws principles.
ACKNOWLEDGMENT:
By opening the package on which this Agreement is printed,
or through which it is visible, you acknowledge that you have
read this Agreement, understand it, and agree that this
agreement is the complete and exclusive statement of
agreement between yourself and Belkin and supersedes any
prior agreements, oral or written, and any other
communications relating to the subject matter of this
Agreement.
SEVERABILITY:
Any term or provision of this Agreement or any application
thereof, which may be prohibited or unenforceable by law in a
particular jurisdiction, shall be interpreted and enforced to the
maximum extent allowed in such jurisdiction (which the parties
acknowledge could mean severing the provision from this
Agreement or, if allowed, enforcing it in a narrower form),
without affecting the remainder of this Agreement, or any
other application of such term or provision in such jurisdiction,
or application of such term or provision in any jurisdiction.
SAFETY INFORMATION
CAUTION!
z
Internal battery voltage is 12V DC.
z
The unit is intended for installation in a controlled
environment (temperature controlled, indoor area free of
conductive contaminants).
z
All batteries used are Sealed Lead Batteries. Batteries must
be recycled.
Recycling Information
Your UPS contains a Non-spillable Sealed Lead Battery. On
the battery, you will find the battery name. Please reference
the chart below for recycling information.
Battery Name
Recycling
Inside the
USA
Recycling Outside
the USA
BB Battery
(800) 278-8599
N/A
CSB Battery
(800) 738-7372
1 (817) 244-4415
VISION Battery
(973) 726-5323
N/A
RITAR Battery
(888) 841-5179
N/A
TROUBLE SHOOTING
PROBLEM
POSSIBLE CAUSE
SOLUTION
On/ Off /Test button
not pushed or pushed
less than 2 second
Press the On/Off
/Test button for more
than 2 seconds
Battery voltage is too
low
Recharge the UPS at
least eight hours
UPS not on,
LED not lit
UPS fault
Contact service
personnel
Power cord loose
Re-plug the power
cord
AC breaker is burned
out or tripped
Replace or reset the
breaker
UPS always
on battery
mode
Ac utility voltage is too
high or too low, or
black out
Normal condition
Battery not fully
charged
Recharge the UPS at
least eight hours
UPS is overload
Remove some
un-necessary loads
Back up time
too short
Charger fault or other
reason
Replace battery.
Contact belkin.com
The UPS
continuously
beeps
Overload
Remove the
non-critical loads
Red LED lit
Battery failure
Replace battery.
Contact belkin.com
CONTACT US
Belkin Components, Ltd
501 West Walnut St.
Compton, CA • 90220-5221 USA
Tel: 310.898.1100
Fax: 310.898.1111
Belkin Components, Ltd
Unit 13 • Gatelodge Close •
Round Spinney
Northampton, NN3 8RX UK
Tel: +44 (0) 1604678300 •
Fax: +44 (0) 1604678330
Belkin Components B.V.
Starparc Building Boeing
Avenue 3331119 PH
Schiphol-Rijk The Netherlands
Tel: +31 (0) 20 654 73 00
Fax: +31 (0) 20 654 73 49
Belkin Australia Ltd
7 Bowen Cresent
West Gosford, NSW 2250
Tel: +61 (02) 4325 4666
Fax: +61 (02) 4325 4277
Please visit
www.Belkin.com
for battery replacement information.
Away from sunlight
Away from heat
Away from
P/N: 50113xxxxx