BenQ TL550 RS232 Commands for PDP and IFP Products - Page 18

H Position

Page 18 highlights

RTC Year 8 ʳ g RTC Month 8 ʳ g RTC Day 8 ʳ g RTC Hour 8 ʳ g RTC Minute 8 ʳ g OSD Rotation 8 ʳ s ʳ ʳʳ ʳ H Monitor 8 ʳ g V Monitor 8 ʳ g H Position 8 ʳ g V Position 8 ʳ g Frame Comp. 8 ʳ g ʳ ʳʳ ʳ Power Save 8 ʳ g ʳ ʳʳ ʳ ʳ ʳʳ ʳ Auto Adjustment 8 ʳ g ʳ ʳʳ ʳ Temperature Alert 8 ʳ g C8 000 ~ 099 C9 001 ~ 012 CA 001 ~ 031 CB 000 ~ 023 CC 000 ~ 059 CF 000: Landscape ʳ 001: Portrait D4 001 ~ 010 D5 001 ~ 010 D6 001 ~ 010 D7 001 ~ 010 D8 000: Off ʳ 001: On D9 000: Off ʳ 001: Low ʳ 002: High DA 000: Off ʳ 001: On DB 000~005: degree The Alert Email will be sent out. When the temperature is reached the "limitied temperature - parameter" Ex: value=012 means Year 2012 If the RTC is not enable, return "Invalid Command Reply" Ex: value=001 means January If the RTC is not enable, return "Invalid Command Reply" If the RTC is not enable, return "Invalid Command Reply" If the RTC is not enable, return "Invalid Command Reply" If the RTC is not enable, return "Invalid Command Reply" ʳ ʳ ʳ ʳ V1.0 18 / 20 Commercial Display RS-232 Protocol

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

________________________________________________________________
V1.0
18
/
20
Commercial Display RS-232 Protocol
RTC Year
8
±
g
C8
000 ~ 099
Ex: value=012 means Year 2012
If the RTC is not enable, return "Invalid
Command Reply"
RTC Month
8
±
g
C9
001 ~ 012
Ex: value=001 means January
If the RTC is not enable, return "Invalid
Command Reply"
RTC Day
8
±
g
CA
001 ~ 031
If the RTC is not enable, return "Invalid
Command Reply"
RTC Hour
8
±
g
CB
000 ~ 023
If the RTC is not enable, return "Invalid
Command Reply"
RTC Minute
8
±
g
CC
000 ~ 059
If the RTC is not enable, return "Invalid
Command Reply"
OSD Rotation
8
±
s
CF
000: Landscape
±
±
±
±
±
001: Portrait
±
H Monitor
8
±
g
D4
001 ~ 010
±
V Monitor
8
±
g
D5
001 ~ 010
±
H Position
8
±
g
D6
001 ~ 010
±
V Position
8
±
g
D7
001 ~ 010
±
rame Comp.
8
±
g
D8
000: Off
±
±
±
±
±
001: On
±
Power Save
8
±
g
D9
000: Off
±
±
±
±
±
001: Low
±
±
±
±
±
002: High
±
Auto
Adjustment
8
±
g
DA
000: Off
±
±
±
±
±
001: On
±
emperature
Alert
8
±
g
DB
000~005: degree
The Alert Email will be sent out. When the
temperature is reached the "limitied
temperature - parameter"
±