Byte2: The Day of the On/Off Timer. bit0

Page 19 highlights

On/Off Timer 14 ʳ g E0 Input value: Byte1 - Byte2 - Byte3...Byte9 (1) Byte1[3:0]: The Number of the On/Off Timer. There are totally 7 On/Off Timers, and this byte is used to selected which timer is going to be accessed. (2) Byte1[7:4] is reserved, should be 0. (3) Byte2~9 are reserverd, should be 0x00. Return value: Byte1 - Byte2 - Byte3...Byte9 (1) Byte1[3:0]: Should retuen the same value See the return value examples below: as Byte1 at Input value. Ex: Byte1=0x01 means the Timer no.1 is Byte1[7]: Reserved, should be 0. selected and disable. Byte1[6]: The Timer is enable or not. Ex: Byte1=0x41 means the Timer no.1 is Byte1[6]=1 means enable. select and enable, and its both On and Off Byte1[5]: The On Timer is enable or not. Timers are disable. Byte1[5]=1 means enable. Ex: Byte1=0x61 means the Timer no.1 is Byte1[4]: The Off Timer is enable or not. select and enable, and its On Timer is enable, Byte1[4]=1 means enable. Off Timer is disable. (2) Byte2: The Day of the On/Off Timer. bit0 Ex: Byte1=0x71 means the Timer no.1 is for Sunday, bit1 for Monday, bit2 for Tuesday, select and enable, and its both On and Off bit3 for Wednesday, bit4 for Thursday, bit5 for Timers are enable. Friday, bit6 for Saturday, bit7 for Everday. Ex: Byte1=0x53 means the Timer no.3 is (3) Byte3: The Hour of the On Timer. select and enable, and its On Timer is Byte3=0x00~0x17. disable, Off Timer is enable. (4) Byte4: The Minute of the On Timer. Ex: Byte2=0x02 means the Timer is on Byte4=0x00~0x3B. Monday. (5) Byte5: The Hour of the Off Timer. Ex: Byte3=0x08, Byte4=0x1E means the On Byte5=0x00~0x17. Timer is at 8:30. (6) Byte6: The Minute of the Off Timer. Ex: Byte5=0x17, Byte6=0x00 means the Off Byte6=0x00~0x3B. Timer is at 23:00. (7) Byte7: Select the Video Source. Ex: Byte7=0x00 means the selected Video 0x00=VGA, 0x01=HDMI1, 0x02=HDMI2, Source is VGA. 0x03=AV, 0x04=YPbPr, 0x05=S-Video, 0x06=DVI, 0x07=DisplayPort, 0x08=SDI, 0x09=Multi-Media. 0x0A=Network, 0x0B=USB Display 0xFF=Default. Other values are reserved. (8) Byte8~9 are reserved, and should be 0x00. V1.0 19 / 20 Commercial Display RS-232 Protocol

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

________________________________________________________________
V1.0
19
/
20
Commercial Display RS-232 Protocol
On/Off Timer
14
±
g
E0
Input value: Byte1 - Byte2 - Byte3…Byte9
(1) Byte1[3:0]: The Number of the On/Off
Timer. There are totally 7 On/Off Timers, and
this byte is used to selected which timer is
going to be accessed.
(2) Byte1[7:4] is reserved, should be 0.
(3) Byte2~9 are reserverd, should be 0x00.
Return value: Byte1 - Byte2 - Byte3…Byte9
(1) Byte1[3:0]: Should retuen the same value
as Byte1 at Input value.
Byte1[7]: Reserved, should be 0.
Byte1[6]: The Timer is enable or not.
Byte1[6]=1 means enable.
Byte1[5]: The On Timer is enable or not.
Byte1[5]=1 means enable.
Byte1[4]: The Off Timer is enable or not.
Byte1[4]=1 means enable.
(2) Byte2: The Day of the On/Off Timer. bit0
for Sunday, bit1 for Monday, bit2 for Tuesday,
bit3 for Wednesday, bit4 for Thursday, bit5 for
Friday, bit6 for Saturday, bit7 for Everday.
(3) Byte3: The Hour of the On Timer.
Byte3=0x00~0x17.
(4) Byte4: The Minute of the On Timer.
Byte4=0x00~0x3B.
(5) Byte5: The Hour of the Off Timer.
Byte5=0x00~0x17.
(6) Byte6: The Minute of the Off Timer.
Byte6=0x00~0x3B.
(7) Byte7: Select the Video Source.
0x00=VGA, 0x01=HDMI1, 0x02=HDMI2,
0x03=AV, 0x04=YPbPr,
0x05=S-Video, 0x06=DVI,
0x07=DisplayPort, 0x08=SDI,
0x09=Multi-Media.
0x0A=Network, 0x0B=USB Display
0xFF=Default. Other values are reserved.
(8) Byte8~9 are reserved, and should be
0x00.
See the return value examples below:
Ex: Byte1=0x01 means the Timer no.1 is
selected and disable.
Ex: Byte1=0x41 means the Timer no.1 is
select and enable, and its both On and Off
Timers are disable.
Ex: Byte1=0x61 means the Timer no.1 is
select and enable, and its On Timer is enable
Off Timer is disable.
Ex: Byte1=0x71 means the Timer no.1 is
select and enable, and its both On and Off
Timers are enable.
Ex: Byte1=0x53 means the Timer no.3 is
select and enable, and its On Timer is
disable, Off Timer is enable.
Ex: Byte2=0x02 means the Timer is on
Monday.
Ex: Byte3=0x08, Byte4=0x1E means the On
Timer is at 8:30.
Ex: Byte5=0x17, Byte6=0x00 means the Off
Timer is at 23:00.
Ex: Byte7=0x00 means the selected Video
Source is VGA.