Biostar M6TSU M6TSU user's manual - Page 92

of RAID 0+1 array. User must replace the failed disk after the computer

Page 92 highlights

Chapter 3 completely finished RAID 0+1 array. Trouble Shooting Note: 1. Four hard disks are needed in the creation of the 0+1 array. 2. In the creation of the 0+1 array, the source disk will actually be the first stripe array composed of two hard disks, the mirror disk will actually be the second stripe array composed of two hard disks. 3. The capacity of the stripe array as the source disk shall be not larger than that of the stripe array as the mirror disk. 4. The capacity of the 0+1 array is equal to that of the stripe array as the source disk. 5. Version 1.11 RAID Administrator does not support disk hot-swapping of RAID 0+1 array. User must replace the failed disk after the computer is turned off, and then rebuild the 0+1 array in BIOS. Suggestion: In order to avoid the capacity waste , please use hard disks with the identical capacity to create the 0+1 array. Warning: The data on all member disks will be destroyed after creating the 0+1 array. 3-27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109

Chapter 3
Trouble Shooting
3-27
completely finished RAID 0+1 array.
Note:
1. Four hard disks are needed in the creation of the 0+1 array.
2. In the creation of the 0+1 array, the source disk will actually be the first
stripe array composed of two hard disks, the mirror disk will actually be
the second stripe array composed of two hard disks.
3. The capacity of the stripe array as the source disk shall be not larger than
that of the stripe array as the mirror disk.
4. The capacity of the 0+1 array is equal to that of the stripe array as the
source disk.
5. Version 1.11 RAID Administrator does not support disk hot-swapping
of RAID 0+1 array. User must replace the failed disk after the computer
is turned off, and then rebuild the 0+1 array in BIOS.
Suggestion:
In order to avoid the capacity waste , please use hard disks with the
identical capacity to create the 0+1 array.
Warning:
The data on all member disks will be destroyed after creating the 0+1
array.