Biostar M7TDF M7TDF compatibility test report - Page 49
Vcore Waveform Measurement-ver1.0
View all Biostar M7TDF manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 49 highlights
VCORE WAVEFORM MEASUREMENT-Ver1.0 Blue cells need to be filled in with lab measurement Yellow cells need to have the overall design tolerance entered VID: Tolerance: +Tolerance - Tolerance 1.475 V 1.00% Overall 0.007 V 0.007 V Vdmm Vscope 1.455 V 1.460 V Vfb_nl 1.460 V Vfb_nf 1.473 V Static Voltage Measurements at pins AC14/AC15 Current Measured Static Voltage 0 1.455 10 1.442 20 1.427 30 1.411 40 1.397 50 1.380 60 1.366 Units V V V V V V V Ripple Voltage Measurements (mV) at pins AC14/AC15 Current Measurement 0 3.600 10 3.600 20 4.000 30 4.800 40 5.200 50 5.200 60 6.000 Units mV mV mV mV mV mV mV 49
49
VCORE WAVEFORM MEASUREMENT-Ver1.0
Blue cells need to be filled in with lab
measurement
Yellow cells need to have the overall design
tolerance entered
VID:
1.475
V
Tolerance:
1.00%
Overall
+Tolerance
0.007
V
- Tolerance
0.007
V
Vdmm
1.455
V
Vscope
1.460
V
Vfb_nl
1.460
V
Vfb_nf
1.473
V
Static Voltage Measurements at pins
AC14/AC15
Current
Measured Static Voltage
Units
0
1.455
V
10
1.442
V
20
1.427
V
30
1.411
V
40
1.397
V
50
1.380
V
60
1.366
V
Ripple Voltage Measurements (mV) at pins
AC14/AC15
Current
Measurement
Units
0
3.600
mV
10
3.600
mV
20
4.000
mV
30
4.800
mV
40
5.200
mV
50
5.200
mV
60
6.000
mV