Biostar M7TDF M7TDF compatibility test report - Page 54
Blue cells need to be filled in with lab measurement
View all Biostar M7TDF manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 54 highlights
Blue cells need to be filled in with lab measurement Yellow cells need to have the overall design tolerance entered VID Voltage: Tolerance: +Tolerance - Tolerance 1.475V 1.00%Overall 0.007V 0.007V Vdmm Vscope 1.452 V 1.466 V Vfb_nl 1.452 V Current 0 10 20 30 40 50 60 Static Voltage Measurements at pins AC14/AC15 Measured Static Voltage Units 1.452 V 1.440 V 1.427 V 1.412 V 1.398 V 1.383 V 1.365 V Ripple Voltage Measurements (mV) at pins AC14/AC15 Current Measurement Units 0 17.600 mV 10 18.800 mV 20 19.000 mV 30 23.000 mV 40 27.200 mV 50 28.200 mV 60 30.200 mV Load Step 0A to 0A 0A to 10A 0A to 20A 0A to 30A 0A to 40A 0A to 50A 0A to 60A Transient Min (mV) at pins AC14/AC15 Current Measurement 0 25.20 10 62.80 20 89.00 30 109.00 40 130.00 50 147.00 60 166.00 Units mV mV mV mV mV mV mV 54