Bosch HBE5453UC Installation Instructions 1 - Page 7

Install Appliance

Page 7 highlights

Flush installation 7RS9LHZ èʌ¼ʓʘ  WRSFOHDW 6LGH9LHZ UHYHDO UHYHDO FOHDWV FOHDWV  IOXVKLQVHW GHSWK  ë  WRSFOHDW ë  èʌ¼ʓʘ    PP UHYHDOFOHDWV ʐ¼ʓʘ  IOXVKFXWRXW KHLJKW * Flush installation requires a 3/16" (5 mm) high x 2115/16" (557 mm) wide x 221/16" (560 mm) deep baseplate underneath the unit body. ** Flush installation under the counter requires a top cleats 3/8" (9 mm) high x 2115/16" (557 mm) wide. This part of furniture must be present, straight and have no gap with the lateral parts.    PP Install Appliance Electrical Installation All model ovens on the front cover are dual rated, designed to be connected to either 208/240V AC, 60 Hz, 4 wire, single-phase power supply. Model HBE5453UC Dedicated circuit required 20 AMP The electrical supply should be a 4-wire single-phase AC. Install a suitable conduit box (not furnished). An appropriately-sized, UL-listed conduit connector must be used to correctly attach the conduit to the junction box. NOTICE: Local Codes may vary; installation, electrical connections and grounding must comply with all applicable local codes. If local codes permit grounding through the electrical supply neutral, connect both the white neutral wire and the bare ground wire from the oven to the white neutral electrical supply wire. 9 CAUTION ▯ The appliance must be disconnected from the power supply during all installation work. ▯ The appliance must only be connected with the power cable provided. ▯ Protection against contact must be ensured by the installation. Electrical Connection The four-wire connection is preferred, but where local codes permit, the three wire connection is also acceptable. 9 WARNING When connected to a 4 or 5-wire, 120/208-Volt 3phase power supply, the phase C conductor is not required for the operation of the appliance. 7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

7
Flush installation
Install Appliance
Electrical Installation
All model ovens on the front cover are dual rated,
designed to be connected to either 208/240V AC,
60 Hz, 4 wire, single-phase power supply.
The electrical supply should be a 4-wire single-phase AC.
Install a suitable conduit box (not furnished). An
appropriately-sized, UL-listed conduit connector must be
used to correctly attach the conduit to the junction box.
NOTICE:
Local Codes may vary; installation, electrical
connections and grounding must comply with all
applicable local codes.
If local codes permit grounding through the electrical
supply neutral, connect both the white neutral wire and
the bare ground wire from the oven to the white neutral
electrical supply wire.
9
CAUTION
The appliance must be disconnected from the
power supply during all installation work.
The appliance must only be connected with the
power cable provided.
Protection against contact must be ensured by
the installation.
Electrical Connection
The four-wire connection is preferred, but where local
codes permit, the three wire connection is also
acceptable.
9
WARNING
When connected to a 4 or 5-wire, 120/208-Volt 3-
phase power supply, the phase C conductor is not
required for the operation of the appliance.
*
Flush installation requires a
3
/
16
" (5 mm) high x
21
15
/
16
" (557 mm) wide x 22
1
/
16
" (560 mm) deep
baseplate underneath the unit body.
**
Flush installation under the counter requires a top
cleats
3
/
8
" (9 mm) high x 21
15
/
16
" (557 mm) wide.
This part of furniture must be present, straight and
have no gap with the lateral parts.
Model
Dedicated circuit required
HBE5453UC
20 AMP