Operating the appliance
View all Bosch HIB82651UC manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 7 highlights
Operating the appliance These instructions apply to several appliance models. It is possible that individual features are described that do not apply to your appliance. Note: Turn the extractor hood on when you start cooking and switch it off again a few minutes after you have finished cooking. This is the most effective way to eliminate cooking vapor. Control panel Explanation 1 Turn the fan down 2 Turn the fan up 3 Display panel 4 Switch on lighting 5 Timer Turn on the fan Note: Always adjust the fan strength to meet current conditions. If there is a large build-up of steam or fumes, select a high fan setting. Switching on ▯ Press "+" button. The current ventilator settings are indicated by a bar on the display panel. ▯ Press "+" or "-" keys to change the ventilator settings. Switching off Press the "-" button repeatedly until the ventilator switches off. Lighting The lighting can be switched on and off independently of the ventilation. 1. Press the "Light" button. The lighting switches on. 2. Press the "Light" button again. The brightness increases. 3. Press the "Light" button a third time. The lighting switches off. Saturation notification The saturation of the metal grease filter (after 30 hours of ventilation operation) or of the activated carbon filter (after 120 hours of ventilation operation) is indicated on the display panel: ▯ Metal grease filter: "clean grease filter" appears on the display panel. ▯ Activated carbon filter: "replace charcoal filter" appears on the display panel. If you have not yet done so, the metal mesh grease filters should be cleaned or the activated carbon filter changed now. For instructions on how to clean the metal grease filters, please refer to the Cleaning and maintenance section. Resetting the saturation displays ▯ Metal grease filter: Press and hold the "+" button for 5 seconds. ▯ Activated carbon filter: Press and hold the "-" button for 5 seconds. Switching over the display for circulating-air mode For circulating-air mode, the electronic control display must be switched over accordingly: ▯ The extractor hood must be connected and switched off. ▯ Press the "+" and "-" keys simultaneously until "Able" lights up briefly on the display panel. ▯ Repeatedly press the button combination to switch the electronic control display back to exhaust air mode. "None" appears on the display panel. Timer The timer has no influence on the functions of the exhaust hood. The duration of the timer can be set to between 1 minute and 60 minutes. The default setting is 10 minutes. 1. Press the "Timer" button. 10 flashes on the display panel. 2. Set the required duration with the "+" and "-" buttons. After 5 seconds, the time that has been set is adopted. An audible signal sounds once the time has elapsed and "End" appears on the display panel for 3 seconds. Note: To switch off the timer earlier, press any button. Fan back flow The run-on time is ten minutes and cannot be changed. 1. Select ventilator setting. 2. Press "Timer" button for 3 seconds. Once this time has elapsed, the ventilation and lighting switch off automatically. The display shows the message "End." The ventilator run-on can be interrupted at any time by pressing one of the buttons. Audible signal Switching on audible signal ▯ Press and hold the "Light" button for 5 seconds. ▯ An audible signal sounds and "Snd" appears on the display panel for 3 seconds. 7