Electrical Installation - GROUNDING INSTRUCTIONS The models stated on the front cover are either dualrated, designed to be connected to either 208/240V AC, 60 Hz, 4-wire, single-phase power supply, or rated at 120V AC, 60 Hz and use a NEMA 5-20 plug to connect to a dedicated 120 V microwave circuit. 208/240 V models may also be combined with some Bosch Built-in Ovens and can be connected directly to the combo appliance. To do this, please refer to detailed instructions with the Bosch Combination Kit. 9 WARNING When connected to a 4 or 5-wire, 120/208-Volt 3phase power supply, the phase C conductor is not required for the operation of the appliance. Model HMCP0252UC HMC80252UC HMC80152UC HMC87152UC Connection Circuit Requirements 4 wire conduit 208 V, 20 Amps cable 60 Hz 240 V, 20 Amps 60 Hz 4 wire conduit 208 V, 20 Amps cable 60 Hz 240 V, 20 Amps 60 Hz NEMA 5-20 120 V, 20 Amps 60 Hz NEMA 5-20 120 V, 20 Amps 60 Hz Electrical Connection with Plug HMC80152UC HMC87152UC Electrical Requirements: ▯ a three prong grounded outlet ▯ 120 V, 60 Hz, AC only ▯ 20 Amp electrical supply with a fuse or a circuit breaker This product must be connected to a supply circuit of the proper voltage and frequency. Wire size must conform to the requirements of the National Electric Code or the prevailing local code for this rating. The power supply cord and plug should be brought to a separate 20-amp branch circuit single grounded outlet. The outlet box should be located in the area behind the appliance (see section Cabinet Dimensions). The outlet box and supply circuit should be installed by a qualified electrician and conform to the National Electrical Code or the prevailing local code. The voltage used must be the same as specified on this microwave oven. Using a higher voltage is dangerous and may result in a fire or oven damage. Using a lower voltage will cause slow cooking. The manufacturer is not responsible for any damages resulting from the use of the oven with any voltage other than specified. 8 Electrical Connection with Wire Conduit HMC80252UC HMCP0252UC The electrical supply should be a 4-wire single-phase AC. Install a suitable conduit box (not furnished). An appropriately-sized, UL-listed conduit connector must be used to correctly attach the conduit to the junction box. 9 WARNING Local codes may vary; installation, electrical connections and grounding must comply with all applicable local codes. If local codes permit grounding through the electrical supply neutral, connect both the white neutral wire and the bare ground wire from the oven to the white neutral electrical supply wire. Electrical Connection The four-wire connection is preferred, but where local codes permit, the three wire connection is also acceptable. 9 WARNING When connected to a 4 or 5-wire, 120/208-Volt 3phase power supply, the phase C conductor is not required for the operation of the appliance. Four-wire Connection Ungrounded Neutral SRZHUVXSSO\ MXQFWLRQER[ UHGZLUHV EODFNZLUHV JUHHQRUEDUH ZLUH JUHHQZLUH 8/OLVWHG FRQQHFWRU ZKLWHZLUHV FDEOHIURP RYHQ ▯ Connect the red oven wire to the red electrical supply wire (hot wire). ▯ Connect the black oven wire to the black electrical supply wire (hot wire). ▯ Connect the white neutral oven wire to the white neutral (not bare or green ground) electrical supply wire. ▯ Connect the green ground oven wire to the bare or green ground electrical supply wire.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

8
Electrical Installation - GROUNDING INSTRUCTIONS
The models stated on the front cover are either dual-
rated, designed to be connected to either 208/240V AC,
60 Hz, 4-wire, single-phase power supply, or rated at
120V AC, 60 Hz and use a NEMA 5-20 plug to connect
to a dedicated 120 V microwave circuit.
208/240 V models may also be combined with some
Bosch Built-in Ovens and can be connected directly to
the combo appliance. To do this, please refer to detailed
instructions with the Bosch Combination Kit.
9
WARNING
When connected to a 4 or 5-wire, 120/208-Volt 3-
phase power supply, the phase C conductor is not
required for the operation of the appliance.
Electrical Connection with Plug
HMC80152UC
HMC87152UC
Electrical Requirements:
a three prong grounded outlet
120 V, 60 Hz, AC only
20 Amp electrical supply with a fuse or a circuit
breaker
This product must be connected to a supply circuit of the
proper voltage and frequency. Wire size must conform to
the requirements of the National Electric Code or the
prevailing local code for this rating. The power supply
cord and plug should be brought to a separate 20-amp
branch circuit single grounded outlet. The outlet box
should be located in the area behind the appliance (see
section
Cabinet Dimensions
). The outlet box and supply
circuit should be installed by a qualified electrician and
conform to the National Electrical Code or the prevailing
local code.
The voltage used must be the same as specified on this
microwave oven. Using a higher voltage is dangerous
and may result in a fire or oven damage. Using a lower
voltage will cause slow cooking. The manufacturer is not
responsible for any damages resulting from the use of
the oven with any voltage other than specified.
Electrical Connection with Wire Conduit
HMC80252UC
HMCP0252UC
The electrical supply should be a 4-wire single-phase AC.
Install a suitable conduit box (not furnished). An
appropriately-sized, UL-listed conduit connector must be
used to correctly attach the conduit to the junction box.
9
WARNING
Local codes may vary; installation, electrical
connections and grounding must comply with all
applicable local codes.
If local codes permit grounding through the electrical
supply neutral, connect both the white neutral wire and
the bare ground wire from the oven to the white neutral
electrical supply wire.
Electrical Connection
The four-wire connection is preferred, but where local
codes permit, the three wire connection is also
acceptable.
9
WARNING
When connected to a 4 or 5-wire, 120/208-Volt 3-
phase power supply, the phase C conductor is not
required for the operation of the appliance.
Four-wire Connection
Ungrounded Neutral
Connect the red oven wire to the red electrical supply
wire (hot wire).
Connect the black oven wire to the black electrical
supply wire (hot wire).
Connect the white neutral oven wire to the white
neutral (not bare or green ground) electrical supply
wire.
Connect the green ground oven wire to the bare or
green ground electrical supply wire.
Model
Connection
Circuit
Requirements
HMCP0252UC
4 wire conduit
cable
208 V,
60 Hz
20 Amps
240 V,
60 Hz
20 Amps
HMC80252UC
4 wire conduit
cable
208 V,
60 Hz
20 Amps
240 V,
60 Hz
20 Amps
HMC80152UC
NEMA 5-20
120 V,
60 Hz
20 Amps
HMC87152UC
NEMA 5-20
120 V,
60 Hz
20 Amps