Bosch PCK755UC Installation Instructions - Page 19

and should be plugged

Page 19 highlights

IMPORTANT INFORMATION All operations relative to installation, adjustment and adaptation to another gas type must be carried out by authorized personnel from our Technical Electrical connection Service, and the codes in force, as well as the requisites of the gas companies must be complied with. 4 - Before connecting the appliance, ensure that Before connecting the power cable to the wall outlet, make sure the gas shut-off valve and all the control knobs of the burners are set to "off". the local connection conditions, as well as the gas The voltage and total power must be checked on type and pressure match the settings of the the specifications plate. This appliance must be appliance. grounded. Ensure that the gas supply is cut off through the Always ensure that all connections have been manual shut-off valve before connecting the made in accordance with code requirements. appliance. Thoroughly follow the requisites of the local The gas connection must be in a place that permits electric power company. access to the manual shut-off valve and that, if necessary, is visible upon opening the kitchen cabinet door. Connect the regulator Figure 3 (2) to the manifold, Figure 3 (1) as shown by the arrow on the regulator The electrical connection (CA 110-127 V) is established by a connection cable with a grounding contact plug connected to a grounded outlet to which there must be access after installation of applying teflon to the threads. the gas cooktop. Connect the pressure regulator to the gas grid using a flexible gas line fitting between the shutoff valve and the pressure regulator. Figure 3. All gas connections must be tested for leaks using an appropriate liquid solution. Never use a flame to test for gas leaks. Figure 3 1 WARNING: this appliance is equipped with a three prong grounding plug for your protection 2 against shock hazard and should be plugged directly into a properly Ensure that a bag containing component 2 is supplied with the appliance. If this component is missing, call our Technical Service. Use the parts we supply to complete the gas connection. Tighten the appliance regulador to 15 to 22 ft-lbs of torque. Never tighten to more than 26 ft-lbs of tor- que. Always use an approved pipe joint compound resistant to the action of LP gas. Connection using a metal pipe. In this case, contact between this tube and the moving parts of the kitchen unit (for example, a drawer) and its passage through areas that could be blocked, must be avoided. The manufacturer accepts no responsibility for leaks or connections carried out by the installation technician. Leak testing according to omf athneufaapcptuliraenrc,seisnhsatrlul cbteiocnosn.ducted grounded receptacle. Do not cut or remove the grounding prong from this plug. The current supply connection cable must be at least of the JT 3x18 AWG/UL/CSA variety, or should be heat-resistant (at least 105 ºC / 221 ºF). The mains connecting cable must only be purchased through and connected by an authorised specialist. Do not tamper with the inside of the appliance. If this is necessary, call our technical assistance service. 18

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

Connect the regulator Figure 3 (2) to the manifold
Figure 3 (1) as shown by the arrow on the regulator
,
applying teflon to the threads.
Connect the pressure regulator to the gas grid
IMPORTANT INFORMATION
Ensure that a bag containing component 2 is
supplied with the appliance. If this component
is missing, call our Technical Service. Use the
parts we supply to complete the gas
connection.
Connection using a metal pipe. In this case, contact
between this tube and the moving parts of the
kitchen unit (for example, a drawer) and its passage
through areas that could be blocked, must be
avoided.
The manufacturer accepts no responsibility for
leaks or connections carried out by the installation
technician.
Figure 3
1
2
The voltage and total power must be checked on
the specifications plate. This appliance must be
grounded.
Always ensure that all connections have been
The electrical connection (CA 110-127 V) is
established by a connection cable with a grounding
contact plug connected to a grounded outlet to
which there must be access after installation of
The current supply connection cable must be at
least of the JT 3x18 AWG/UL/CSA variety, or
should be heat-resistant (at least 105
º
C / 221
º
F).
Do not tamper with the inside of the appliance.
If this is necessary, call our technical assistance
service.
Electrical connection
Before connecting the power cable to the wall
off valve and the pressure regulator. Figure 3.
using a flexible gas line fitting between the shut-
the gas cooktop.
the control knobs of the burners are set to "off".
outlet, make sure the gas shut-off valve and all
authorised specialist.
The mains connecting cable must only be
purchased through and connected by an
Tighten the appliance regulador to 15 to 22 ft-lbs of
torque. Never tighten to more than 26 ft-lbs of tor-
resistant to the action of LP gas.
made in accordance with code requirements.
Thoroughly follow the requisites of the local
electric power company.
All gas connections must be tested for leaks using
an appropriate liquid solution.
Never use a flame
to test for gas leaks.
grounding prong from
this plug.
Do not cut or remove the
grounded receptacle.
directly into a properly
and should be plugged
against shock hazard
plug for your protection
a three prong grounding
appliance is equipped with
WARNING: this
que. Always use an approved pipe joint compound
,
Leak testing of the appliance shall be conducted
according to manufacturer
s
instructions.
The gas connection must be in a place that permits
access to the manual shut-off valve and that, if
necessary, is visible upon opening the kitchen
cabinet door.
Ensure that the gas supply is cut off through the
manual shut-off valve before connecting the
appliance.
All operations relative to installation, adjustment
and adaptation to another gas type must be carried
out by authorized personnel from our Technical
requisites of the gas companies must be complied
with.
the local connection conditions, as well as the gas
type and pressure match the settings of the
appliance.
Service, and the codes in force, as well as the
4 -
Before connecting the appliance, ensure that
18