Brother International 8060P Owners Manual - Page 156
The drum unit is a consumble and it is necessary to replace it, periodically., DIFFICULTY, SUGGESTIONS
View all Brother International 8060P manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 156 highlights
146 C H A P T E R S E V E N T E E N DIFFICULTY Toner scatters and stains the printed page. Scattering Toner SUGGESTIONS Adjust the print conditions by setting the Print Density function. Clean the machine's interior. See "Regular Maintenance" and "Cleaning the Drum Unit" in this chapter. Make sure that you use paper that meets specifications. See chap. 13. If you still have scattered toner and the display shows CHANGE DRUM SOON, replace the drum unit with a new one. The whole page is printed black. Black Page Wipe the electric terminals. Also, do not use heatsensitive paper as it will cause this problem. After cleaning, if the printed pages are still black and the display shows CHANGE DRUM SOON, replace the drum unit with a new one. Nothing is printed on the page. White page Make sure that the toner cartridge is not empty. Wipe the electric terminals referring to "Regular Maintenance" and "Cleaning the Drum Unit" in this chapter. Make sure that a torn piece of paper does not remain on the scanner window. Printed pages are marked Markings may disappear by themselves. Try copying at regular intervals. multiple pages to clear this problem. Markings may occur if the machine has not been used for a long time. A possible cause is that the surface of the drum is marked or damaged by excessive exposure to light. In this case, replace Example of Regular Marking the drum unit with a new one. Printed pages are blurred at Certain environmental conditions such as humidity, high the center or at either edge. temperatures, etc. may cause this condition to occur. Make sure the machine is placed on a flat, horizontal surface. Remove the drum unit with the toner cartridge installed. Try rocking them from side to side. You may clear a blurred page by wiping the scanner windows with a clean soft cloth. (See "Regular Maintenance" and "Cleaning the Drum Unit" in this chapter.) If a blurred page occurs after Blurred Page cleaning and the display shows CHANGE DRUM SOON, replace the drum unit with a new one. Ghost images appear on printed page. ,,,,,,,, Ghost Images Adjust the print conditions by setting the Print Density function. Make sure that you use paper that meets the specifications. Rough surfaces or thick media can cause a ghost image. The drum unit is a consumble and it is necessary to replace it periodically.