Brother International BES-1210AC Color Change Potentiometer Replacement - Engl - Page 2

Press the Needle Select button

Page 2 highlights

Remove the mounting bracket from the old color change potentiometer with a wrench and install on the new potentiometer in the same orientation as the old one. Mounting Bracket Plug the new color change potentiometer connector into the thread tension bracket connector but do not install the potentiometer onto the machine. Turn on power to the machine. Press the Needle Select button to display the needle bar selection screen. Turn the color change collar to move the needle bar case to where it is positioned between needles 1 and 2 as illustrated. Turn the shaft of the color change potentiometer so that needles 1 and 2 are flashing on the needle bar selection screen.

  • 1
  • 2
  • 3

Remove the mounting bracket from the old color change potentiometer with a
wrench and install on the new potentiometer in the same orientation as the old
one.
Plug the new color change potentiometer connector into the thread tension
bracket connector but do not install the potentiometer onto the machine.
Turn on power to the machine.
Press the Needle Select button
to display the needle bar selection screen.
Turn the color change collar to move the needle bar case to where it is
positioned between needles 1 and 2 as illustrated.
Turn the shaft of the color change potentiometer so that needles 1 and 2 are
flashing on the needle bar selection screen.
Mounting Bracket