Chapter 9 Error code list Code Error Messages E-E3 Exhaust fan motor stop E-E5 ERROR E5 E-E6 ERROR E6 E-E7 ERROR E7 E-E8 ERROR E8 E-E9 ERROR E9 E-EA ERROR EA E-EB ERROR EB E-EC ERROR EC E-ED ERROR ED E-EF ERROR EF E-F1 ERROR F1 E-F2 ERROR F2 E-F3 ERROR F3 E-F4 ERROR F4 E-F5 ERROR F5 E-F6 ERROR F6 E-F7 ERROR F7 E-F8 ERROR F8 E-F9 ERROR F9 E-FA ERROR FA E-FB ERROR FB E-FF ERROR FF Error Measures Cooling fan motor stop. Over-run error during interfacing to main PCB CPU Framing error during interfacing to main PCB CPU Turn off the power and check the fan harness. Turn on the power again. If the same error occurs again, the fan or the main PCB is faulty. Parity error during interfacing to main PCB CPU Receiving time up error during interfacing to main PCB CPU Send/Receive inconsistent error during interfacing to main PCB CPU ACK code receiving error during interfacing to main PCB CPU Send/Receive ID code error during interfacing to main PCB CPU Send data checksum error during interfacing to main PCB CPU Data empty error during interfacing to main PCB CPU Receiving error on interface Send time up error Request-to-waiting time up error This is not usually displayed. Request-to-recive time up error Receive command error NACK code receiving error Data requested for needle position can not be returned. It is not receive command for the request one. PRE code error No applicable command Interface receive data sum check error Send time up error No status is returned from main shaft CPU. 142 BES-916AC • BES-1216AC