4. Presser foot mechanism 0 0 0-4 0 0 Feed dog • •• 0 6 mm (1) Insert the presser bar 0 into the presser bar guide bracket from above the arm and lightly tighten the screw 0. (2) Insert the presser spring guide into the presser spring 0 and secure it with the presser adjusting screw and the nut O. (3) After raising the presser bar 0 using the presser bar lifter (3, secure the presser foot Oand the sensor guard ©with the screw (D. 0 (4) Adjust the presser foot to approximately 6 mm above the needle plate by removing the face plate cap 0. © and loosening the screw 0. Then fasten the screw 5. Needle bar mechanism 0 M-\41 me' Needle bar bracket bushing 0 (1) Insert the needle bar bracket 0 into the needle bar bracket bushing and the set collar 0. Then fasten the screw O. (2) Secure the needle feed arm and the needle feed link © through the stud O to the needle bar bracket 0 with the screws 0 and O. (3) Secure the needle bar bracket guide ©with the two screws O. (4) Insert the needle bar fD into the needle bar clamp 0 from above the arm, and fasten the screw ID. (5) Install the oil caps m and ®. - 29 -