Brother International TD-2020 ESC/ P Command Reference - Page 91
ESC i M 2D barcode (MaxiCode), Maximum Amount of Information Allowed
View all Brother International TD-2020 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 91 highlights
ESC/P Command Reference ESC i M 2D barcode (MaxiCode) ASCII: ESC i M or m data Decimal: 27 105 77 or 109 data Hexadecimal: 1B 69 4D or 6D data Format: ESC i M or m [Parameters] \ (1) (2) [Barcode data] \\\ (3) (4) Parameters (1) [Parameters] If a value other than those listed is entered for a parameter, that parameter is specified with its default value. 1. Symbol type [1-byte decimal] 0 [1-byte decimal] 1 [1-byte decimal] 2 Standard (default value) Full EEC Structured carrier message 2. Structured [1-byte decimal] 0 Append [1-byte decimal] 1 setting With Structured Append (default value) Without Structured Append (2) \ (backslash) Separator between parameters and barcode data (3) [Barcode data]: Barcode data The number of barcode data characters that can be entered is listed below. Symbol Type Maximum Amount of Information Allowed Alphanumeric Characters Numbers Standard 93 138 Full EEC 77 113 Structured carrier message 84 126 Note The numbers of characters that can be entered (as listed above) are for when using only the common character set (code set A in the MaxiCode specifications). The number of characters that can be entered may decrease, depending on the characters that are used. - 85 - 5. Control Command Details