Brother International Z-8560A Instruction Manual - English - Page 32

When the TEST key is pressed, the TEST icon 25 illuminates. In this condition,

Page 32 highlights

6. USING THE OPERATION PANEL (BASIC OPERATIONS) (18) Start backtack key [Z-40 only] When this key is pressed so that the indicator illuminates, the number of start backtack stitches (0−99) in the A and B stitch number displays is sewn. 3406M (19) End backtack key [Z-40 only] When this key is pressed so that the indicator illuminates, the number of end backtack stitches (0−99) in the C and D stitch number displays is sewn. When the treadle is depressed backward, the end backtack stitches are sewn and then the thread is trimmed automatically. • If the treadle has not yet been depressed backward, the end backtack function can be set to ON, the number of stitches can be changed and the function can be set back to OFF. 3407M (20) Continuous backtack key [Z-40 only] When this key is pressed so that the indicator illuminates, the number of backtack stitches (0−99) in the A, B, C and D stitch number displays is sewn continuously. After the sewing machine sews a full cycle of stitches set by A, B, C and D, the thread is trimmed automatically. 2142M (21) Fixed stitch/name label key [Z-40 only] When this key is pressed so that the indicator illuminates while the number of stitches set for F is "0", the number of stitches set for E (1−250) that appears in the main display is sewn, and then sewing stops automatically. When this key is pressed so that the indicator illuminates while the number of stitches set for F is something other than "0", fixed stitch sewing is carried out repeatedly for the number of stitches set for E and F (1−250) that appears in the main display . 3408M (22) AUTO key [Z-40 only] This can only be used to make settings together with continuous backtack key (20) and fixed stitch/name label key (21). • When this key is pressed so that the indicator illuminates, the set number of stitches (start or end backtack stitches, fixed stitches or thread trimming) are sewn automatically simply by depressing the treadle once. 2147M (23) TEST key This key is used when adjusting the needle and rotary hook timing. icon • When the TEST key is pressed, the TEST icon (25) illuminates. In this condition, the sewing machine motor will not operate even if the treadle is depressed. Needle zigzag movement can be carried out by turning the machine pulley by hand. • If the TEST key is pressed once more, the icon (25) will switch off and the sewing machine will return to the normal state of operation. 3409M (24) Thread trimming lock key [Z-40 only] When this key is pressed so that the indicator illuminates, the sewing machine stops in the needle up position without thread trimming being carried out even if the treadle is depressed backward. • If the AUTO key (22) is illuminated, the sewing machine stops in the needle up position without thread trimming being carried out after the set number of stitches have been sewn. 2152M (25) TEST icon This illuminates when the TEST key (23) is pressed. 3410M (26) Zigzag base line position icon This illuminates when the zigzag base line position is being displayed in the main display. 3411M (27) Backtack zigzag width icon This illuminates when the backtack zigzag width is being displayed in the main display . (28) Zigzag width icon This illuminates when the zigzag width is being displayed in the main display . 3412M 3413M Z-8550A, 8560A 24

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90

Z-8550A, 8560A
6. USING THE OPERATION PANEL (BASIC OPERATIONS)
24
(18)
Start backtack key [Z-40 only]
When this key is pressed so that the indicator illuminates, the number of start backtack
stitches (0
99) in the A and B stitch number displays is sewn.
(19)
End backtack key [Z-40 only]
When this key is pressed so that the indicator illuminates, the number of end backtack
stitches (0
99) in the C and D stitch number displays is sewn. When the treadle is
depressed backward, the end backtack stitches are sewn and then the thread is trimmed
automatically.
If the treadle has not yet been depressed backward, the end backtack function can be
set to ON, the number of stitches can be changed and the function can be set back to
OFF.
(20)
Continuous backtack key [Z-40 only]
When this key is pressed so that the indicator illuminates, the number of backtack stitches
(0
99) in the A, B, C and D stitch number displays is sewn continuously. After the sewing
machine sews a full cycle of stitches set by A, B, C and D, the thread is trimmed
automatically.
(21)
Fixed stitch/name label key [Z-40 only]
When this key is pressed so that the indicator illuminates while the number of stitches set
for F is “0”, the number of stitches set for E (1
250) that appears in the main display is
sewn, and then sewing stops automatically.
When this key is pressed so that the indicator illuminates while the number of stitches set
for F is something other than “0”, fixed stitch sewing is carried out repeatedly for the
number of stitches set for E and F (1
250) that appears in the main display .
(22)
AUTO key [Z-40 only]
This can only be used to make settings together with continuous backtack key (20) and
fixed stitch/name label key (21).
When this key is pressed so that the indicator illuminates, the set number of stitches
(start or end backtack stitches, fixed stitches or thread trimming) are sewn automatically
simply by depressing the treadle once.
(23)
TEST key
This key is used when adjusting the needle and rotary hook timing. icon
When the TEST key is pressed, the TEST icon (25) illuminates. In this condition, the
sewing machine motor will not operate even if the treadle is depressed. Needle zigzag
movement can be carried out by turning the machine pulley by hand.
If the TEST key is pressed once more, the icon (25) will switch off and the sewing
machine will return to the normal state of operation.
(24)
Thread trimming lock key [Z-40 only]
When this key is pressed so that the indicator illuminates, the sewing machine stops in the
needle up position without thread trimming being carried out even if the treadle is
depressed backward.
If the AUTO key (22) is illuminated, the sewing machine stops in the needle up position
without thread trimming being carried out after the set number of stitches have been
sewn.
(25)
TEST icon
This illuminates when the TEST key (23) is pressed.
(26)
Zigzag base line position icon
This illuminates when the zigzag base line position is being displayed in the main display.
(27)
Backtack zigzag width icon
This illuminates when the backtack zigzag width is being displayed in the main display .
(28)
Zigzag width icon
This illuminates when the zigzag width is being displayed in the main display .
3406M
3407M
2142M
3408M
2147M
3409M
2152M
3410M
3411M
3412M
3413M