Campbell Scientific 109 109-L Temperature Probe - Page 11

Maximum, Steinhart-Hart, Linearization Error, Probe Length, Probe Diameter, Weight with 10 ft Cable

Page 11 highlights

Model 109 Temperature Probe Maximum Steinhart-Hart Linearization Error: 0.03 °C at -50 °C Error Degrees C Steinhart & Hart - Tabulated values 0.03 0.025 0.02 0.015 0.01 0.005 0 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 70 -0.005 Temperature Degrees C FIGURE 6-1. Steinhart and Hart Possible Error Degrees C Worst Case Errors in 109 Temperature Measurement 0.7 Thermistor Tolerance CR200 Bridge Measurement Error (0.06% of reading+2.4 mV) 0.6 CR10X Bridge Measurement Error, CR200 Resolution (0.5 mV, 0.6 mV) 0.5 24.9 k Ohm Fixed Resistor Tolerance (0.1% + 10ppm/degC away from 25deg) 0.4 0.3 0.2 0.1 6E-16 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 70 -0.1 Temperature Degrees C FIGURE 6-2. Possible Errors 1The overall probe accuracy is a combination of the thermistor interchangeability specification, the accuracy of the bridge resistor, and the Steinhart-Hart equation used in CRBasic instruction Therm109() (CRBasic dataloggers). The major error component is the interchangeability specification of the thermistor. The bridge resistor has a 0.1% tolerance with a 10 ppm temperature coefficient. At temperature extremes, the possible error in the CR200(X) series measurement may be greater than the error that may exist in the probe. Probe Length: Probe Diameter: Weight with 10 ft Cable: 10.4 cm (4.1 in) 0.762 cm (0.3 in) 136 g (5 oz) 5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

Model 109 Temperature Probe
Maximum
Steinhart-Hart
Linearization Error:
0.03 °C at –50 °C
FIGURE 6-1.
Steinhart and Hart
FIGURE 6-2.
Possible Errors
1
The overall probe accuracy is a combination of the thermistor interchangeability specification,
the accuracy of the bridge resistor, and the Steinhart-Hart equation used in CRBasic instruction
Therm109()
(CRBasic dataloggers).
The major error component is the interchangeability
specification of the thermistor.
The bridge resistor has a 0.1% tolerance with a 10 ppm
temperature coefficient.
At temperature extremes, the possible error in the CR200(X) series
measurement may be greater than the error that may exist in the probe.
Probe Length:
10.4 cm (4.1 in)
Probe Diameter:
0.762 cm (0.3 in)
Weight with 10 ft Cable:
136 g (5 oz)
-0.005
0
0.005
0.01
0.015
0.02
0.025
0.03
-50
-40
-30
-20
-10
0
10
20
30
40
50
60
70
Error Degrees C
Temperature Degrees C
Steinhart & Hart
- Tabulated values
-0.1
6E-16
0.1
0.2
0.3
0.4
0.5
0.6
0.7
-50
-40
-30
-20
-10
0
10
20
30
40
50
60
70
Possible Error Degrees C
Temperature Degrees C
Worst Case Errors in 109 Temperature Measurement
Thermistor Tolerance
CR200 Bridge Measurement Error (0.06% of reading+2.4 mV)
CR10X Bridge Measurement Error, CR200 Resolution (0.5 mV, 0.6 mV)
24.9 k Ohm Fixed Resistor Tolerance (0.1% + 10ppm/degC away from
25deg)
5