A150 Desiccated Case 1. Function 1.1 Typical Applications The A150 desiccated case is a small, self-contained junction box that allows a sensor to be connected to a continuation cable, a PWENC connector, or a CWS900 wireless sensor connector. Utilizing the A150, a sensor may be incorporated into a wireless sensor network or may be attached to a prewired enclosure. Lid Chassis Cable Gland Mounting Bracket FIGURE 1. A150 Desiccated Case The A150 allows the CS450 and CS455 pressure transducers to be used without the need to run a ventilation tube all the way to a datalogger enclosure. The sensor cable with a ventilation tube terminates at the A150, which contains a small vent and desiccant, while a second cable without a ventilation tube completes the connection to the datalogger. The A150 provides a way for a sensor to be included in a wireless sensor network. The sensor is attached to the A150 junction box, and a second cable attaches the A150 to a CWS900 wireless sensor interface. This allows the sensor more flexibility and range than it would have if it were wired directly to a datalogger. 1.2 Compatibility As a junction box, the A150 is compatible with most sensors using six wires or less. Sensors with multiple ground wires can use the included 5-position lever nut to combine the grounds into a single wire connection. 1

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

A150 Desiccated Case
1.
Function
1.1
Typical Applications
The A150 desiccated case is a small, self-contained junction box
that allows a
sensor to be connected to a continuation cable, a PWENC connector, or a
CWS900 wireless sensor connector.
Utilizing the A150, a sensor may be
incorporated into a wireless sensor network or may be attached to a prewired
enclosure.
Mounting Bracket
Cable Gland
Chassis
Lid
FIGURE 1.
A150 Desiccated Case
The A150 allows the CS450 and CS455 pressure transducers to be used
without the need to run a ventilation tube all the way to a datalogger enclosure.
The sensor cable with a ventilation tube terminates at the A150, which contains
a small vent and desiccant, while a second cable without a ventilation tube
completes the connection to the datalogger.
The A150 provides a way for a sensor to be included in a wireless sensor
network.
The sensor is attached to the A150 junction box, and a second cable
attaches the A150 to a CWS900 wireless sensor interface.
This allows the
sensor more flexibility and range than it would have if it were wired directly to
a datalogger.
1.2
Compatibility
As a junction box, the A150 is compatible with most sensors using six wires or
less.
Sensors with multiple ground wires can use the included 5-position lever
nut to combine the grounds into a single wire connection.
1