Campbell Scientific CR10X TD Operating System Addendum for CR510, CR10X, and C - Page 47

PakBus Get/Send Locations P190

Page 47 highlights

Section 12. Program Control Instructions Radio Settings CR205 Power Mode and Header RF400 on CR10X or CR23X Beacon Interval RF400 on computer LoggerNet Settings When RF400 with direct access to network is connected to computer. Stand Alone SendGetData P190 Wireless Sensor P193 Datalogger Radio address, net address, and hop sequence must be the same in all CR2xxs and RF400s in the network. Because only one header length can be set for a radio, only one power cycling interval should be used in network; i.e., do not mix 8 second and 1 second interval radio power cycling. RF on (no cycling) is specified where necessary below. Select power mode for Select power mode for NO HEADER. appropriate response appropriate response RfpinEn (lowest power) time and current drain. time and current drain. or to allow communi- Header must match cation with computer for called station's cycle. checking station, down- loading program: RF8_Sec or RF1_sec. Router, if used, must Router, if used, must RF on, header to match send appropriate header send appropriate header CR205 setting to allow contacting CR205 0 0 0 RF on, header to match RF on, header to match RF on, header to match neighbors' settings neighbors' settings neighbors' settings For each datalogger: For each datalogger For each master with stored data: datalogger: Com Com Com -PbusPort -PbusPort -PbusPort -logger -logger -logger PakBus Get/Send Locations (P190) A program control instruction that sends data to or retrieves data from another datalogger in a PakBus network. This instruction can also be used to issue commands to Modbus devices, where the datalogger acts as a Modbus master. 1: PakBus - Get/Send Locations (P190) 1: 00 Port 2: 0000 Address 3: 00 Command 4: 0000 Security 5: 0000 Remote Loc/Coil/Register 6: 0000 Swath 7: 0000 Local Loc 8: 0000 Result Code Loc 12-3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62

Section 12.
Program Control Instructions
12-3
Stand Alone
Datalogger
SendGetData P190
Wireless Sensor P193
Radio Settings
Radio address, net address, and hop sequence must be the same in all CR2xxs
and RF400s in the network. Because only one header length can be set for a
radio, only one power cycling interval should be used in network; i.e., do not
mix 8 second and 1 second interval radio power cycling. RF on (no cycling) is
specified where necessary below.
CR205
Power Mode and
Header
Select power mode for
appropriate response
time and current drain.
Select power mode for
appropriate response
time and current drain.
Header must match
called station’s cycle.
NO HEADER.
RfpinEn (lowest power)
or to allow communi-
cation with computer for
checking station, down-
loading program:
RF8_Sec or RF1_sec.
RF400 on CR10X
or CR23X
Router, if used, must
send appropriate header
Router, if used, must
send appropriate header
RF on,
header to match
CR205 setting to allow
contacting CR205
Beacon Interval
0
0
0
RF400 on computer
RF on,
header to match
neighbors’ settings
RF on,
header to match
neighbors’ settings
RF on,
header to match
neighbors’ settings
LoggerNet Settings
When RF400 with direct
access to network is
connected to computer.
For each datalogger:
Com
-PbusPort
-logger
For each datalogger
with stored data:
Com
-PbusPort
-logger
For each master
datalogger:
Com
-PbusPort
-logger
PakBus Get/Send Locations (P190)
A program control instruction that sends data to or retrieves data from another
datalogger in a PakBus network. This instruction can also be used to issue
commands to Modbus devices, where the datalogger acts as a Modbus master.
1:
PakBus - Get/Send Locations (P190)
1: 00
Port
2: 0000
Address
3: 00
Command
4: 0000
Security
5: 0000
Remote Loc/Coil/Register
6: 0000
Swath
7: 0000
Local Loc [ ______________ ]
8: 0000
Result Code Loc [ ______________ ]