Campbell Scientific CR200X CR200/CR200X-series Dataloggers - Page 190

Table 27., CR200X Settings, Device, PB Address

Page 190 highlights

Appendix B. Status Table and Settings Table 27. CR200(X) Settings Settings are accessed through Campbell Scientific's Device Configuration Utility (DevConfig) for direct serial connection, or through PakBusGraph for most telecommunications options. Setting Description Default Entry Max Packet Size Specified the maximum size packet in bytes that should ever be 1000 sent to the device. PakBus Address This setting specifies the PakBus® address for this device. The 1 value for this setting must be chosen such that the address of the device is unique in the scope of the datalogger network. Duplication of PakBus® addresses in two or more devices can lead to failures and unpredictable behavior in the PakBus® network. The following values are the default addresses of various types of software and devices and should probably be avoided: Device PB Address LoggerNet 4094 PC400 4093 PC200 4092 Visual Weather 4091 RTDAQ 4090 DevConfig 4089 NL100 678 All other devices 1 Radio Installed Specifies the model number of the MaxStream radio if it is recognized by the datalogger. It will have a value of zero if there is no radio recognized by the datalogger. RF Network Address Specifies the radio network address of the built-in radio. This 0 setting should be set to match the network address for the RF400 base used to communicate with the datalogger. RF Address Specifies the address of the built-in radio. This value should 0 generally be set to match the same as the address of the RF400 base used to communicated with the datalogger unless that base is used to communicate with non-PakBus® dataloggers (such as a CR10X). RF Hop Sequence Specifies the hopping sequence that will be used for the built-in 0 radio. This value should be set to match the value of the same setting for the RF400 base station used to communicate with this datalogger Ignore RF Power Mode If set to true (non-zero value), the RF power mode setting will 0 be ignored and the radio will be powered on all of the time. RF Power Mode This setting specifies the power wait state that will be set in the 50 built-in radio. This setting must be set so that the standby mode of the radio is consistent with any other CR200(X) or RF400/RF410/Rf415 with which this station must communicate. The power modes supported include the following: No Radio Indicates that there is no radio hardware recognized by the datalogger. The datalogger will not accept this value as an input, but will report it if there is no radio hardware detected. Always On Indicates that the radio receiver circuit should always be ready to receive data. 18

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208

Appendix B.
Status Table and Settings
Table 27.
CR200(X) Settings
Settings are accessed through Campbell Scientific's Device Configuration Utility (DevConfig) for direct serial
connection, or through PakBusGraph for most telecommunications options.
Setting
Description
Default Entry
Max Packet Size
Specified the maximum size packet in bytes that should ever be
sent to the device.
1000
PakBus Address
This setting specifies the PakBus® address for this device. The
value for this setting must be chosen such that the address of
the device is unique in the scope of the datalogger network.
Duplication of PakBus® addresses in two or more devices can
lead to failures and unpredictable behavior in the PakBus®
network. The following values are the default addresses of
various types of software and devices and should probably be
avoided:
Device
PB Address
LoggerNet
4094
PC400
4093
PC200
4092
Visual Weather
4091
RTDAQ
4090
DevConfig
4089
NL100
678
All other devices
1
1
Radio Installed
Specifies the model number of the MaxStream radio if it is
recognized by the datalogger. It will have a value of zero if
there is no radio recognized by the datalogger.
RF Network Address
Specifies the radio network address of the built-in radio. This
setting should be set to match the network address for the
RF400 base used to communicate with the datalogger.
0
RF Address
Specifies the address of the built-in radio. This value should
generally be set to match the same as the address of the
RF400 base used to communicated with the datalogger unless
that base is used to communicate with non-PakBus®
dataloggers (such as a CR10X).
0
RF Hop Sequence
Specifies the hopping sequence that will be used for the built-in
radio. This value should be set to match the value of the same
setting for the RF400 base station used to communicate with
this datalogger
0
Ignore RF Power Mode
If set to true (non-zero value), the RF power mode setting will
be ignored and the radio will be powered on all of the time.
0
RF Power Mode
This setting specifies the power wait state that will be set in the
built-in radio. This setting must be set so that the standby mode
of the radio is consistent with any other CR200(X) or
RF400/RF410/Rf415 with which this station must communicate.
The power modes supported include the following:
No Radio
Indicates that there is no radio hardware recognized by the
datalogger. The datalogger will not accept this value as an
input, but will report it if there is no radio hardware detected.
Always On
Indicates that the radio receiver circuit should always be ready
to receive data.
50