Campbell Scientific NL120 NL120 Ethernet Module - Page 10

Specifications

Page 10 highlights

NL120 Ethernet Module FIGURE 4-2. LoggerNet setup 4.2.3 Step 3 - Connect You are now ready to connect to your datalogger using the LoggerNet Connect screen. Datalogger program transfer, table-data display, and data collection are now possible. 5. Specifications Datalogger Compatibility: CR1000, CR3000 Power Requirements: 12 V supplied through datalogger's peripheral port Typical Current Drain: 20 mA (Note: To save power, the IPNetPower() instruction can be used to turn off power to the NL120. See the CRBasic help for an example of using the IPNetPower instruction.) Operating Temp. Range: EMI and ESD Protection: -25° to +50°C Standard -40° to +85°C Extended Meets requirements for a class-A device under European Standards Application of Council Directive(s): 89/336/EEC as amended by 89/336/EEC and 93/68/EEC Standards to which conformity is declared: EN55022-1: 1995 and EN50082-1: 1992 4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

NL120 Ethernet Module
FIGURE 4-2.
LoggerNet setup
4.2.3 Step 3 – Connect
You are now ready to connect to your datalogger using the LoggerNet Connect
screen.
Datalogger program transfer, table-data display, and data collection are now
possible.
5.
Specifications
Datalogger Compatibility:
CR1000, CR3000
Power Requirements:
12 V supplied through datalogger’s peripheral
port
Typical Current Drain:
20 mA
(Note: To save power, the IPNetPower()
instruction can be used to turn off power to the
NL120. See the CRBasic help for an example
of using the IPNetPower instruction.)
Operating Temp. Range:
–25
°
to +50
°
C Standard
–40
°
to +85
°
C Extended
EMI and ESD Protection:
Meets requirements for a class-A device under
European Standards
Application of Council Directive(s):
89/336/EEC as amended by 89/336/EEC and
93/68/EEC
Standards to which conformity is declared:
EN55022-1: 1995 and EN50082-1: 1992
4